Verified Questions with Answers, 2025
Quiz_________________?
4 X 8 inch cylinders that are rodded should be filled in 3 layers of equal volume. (T or F) -
Answers✅
Quiz_________________?
A composite sample is not needed if only the temperature test is being run. (T or F) -
Answers✅
True
Quiz_________________?
According to ASTM C1064, what is one reason to take the temperature of concrete? -
Answers✅
Verify conformance
1
, Quiz_________________?
According to ASTM C138, after rodding each layer, tap the sides of the container, with the
rod exactly 25 times. (T or F) -
Answers✅
False
Quiz_________________?
According to ASTM C138, when rodding the bottom layer, the rod shall not forcibly strike
the bottom of the measure. (T or F) -
Answers✅
True
Quiz_________________?
According to ASTM C143, it is permissible to use a mold, which clamps to a non-absorbent
base. (T or F) -
Answers✅
True
Quiz_________________?
According to C138, concretes with slumps of 1-3 inches may be compacted with the
vibrator or the rod. (T or F) -
Answers✅
True
Quiz_________________?
2
, After consolidation, if the measure contains a great excess of material, remove a quantity of
representative concrete then strike off the surface. (T or F) -
Answers✅
True
Quiz_________________?
After sampling is completed, start the tests for slump and air content within: -
Answers✅
None of the above (5 mins)
Quiz_________________?
After strike-off, the next operation is: -
Answers✅
Clean the excess concrete from the exterior of the measure
Quiz_________________?
After the meter had been rolled twice with no change in the liquid level and no foam on the
surface of the liquid, the direct reading of the liquid in the neck was 3.25%. What was the air
content of the concrete? The aggregate correction factor is 0.3% & 2 pints of alcohol were
added initially. -
Answers✅
Quiz_________________?
After the thermometer is placed in the concrete: -
Answers✅
3