KY HVAC JOURNEYMAN 200 EXAM QUESTIONS AND PREP TEST EXAM 2026/2027 || HEATING, VENTILATION & AIR CONDITIONING LICENSING REVIEW || CODES, INSTALLATION, TROUBLESHOOTING & SAFETY || 200 PRACTICE QUESTIONS WITH VERIFIED ANSWERS || HIGH-YIELD STUDY GUIDE || GRADED A+ 200 exam questions with correct answers Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ : a: 200°F b: 250°F c: 350°F d: 325°F - CORRECT ANSWER -d: 325°F Refer: IMC Code 605.1 Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: a: 10 inches b: 12 inches c: 16 inches d: 14 inches - CORRECT ANSWER -b: 12 inches Refer: IMC Code 801.12 Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes under ________ combustible liquid: a: Class I b: Class II c: Class IIIA d: Class IIIB - CORRECT ANSWER -b: Class II Where located adjacent to walkways, the vertical termination of mechanical draft systems shall be not less than ______ above the level of the walkway:

Show more Read less
Institution
KY HVAC JOURNEYMAN 200
Course
KY HVAC JOURNEYMAN 200

Content preview

KY HVAC JOURNEYMAN 200 EXAM QUESTIONS AND PREP TEST
EXAM 2026/2027 || HEATING, VENTILATION & AIR CONDITIONING
LICENSING REVIEW || CODES, INSTALLATION, TROUBLESHOOTING
& SAFETY || 200 PRACTICE QUESTIONS WITH VERIFIED ANSWERS ||
HIGH-YIELD STUDY GUIDE || GRADED A+



200 exam questions with correct answers
Liquid adhesive coatings used on air filters for air conditioning or heating
systems shall have a flash point not lower than _______ :
a: 200°F
b: 250°F
c: 350°F
d: 325°F - CORRECT ANSWER -d: 325°F
Refer: IMC Code 605.1


Connectors shall connect to a chimney flue at a point not less than ______
above the lowest portion of the interior of the chimney flue:
a: 10 inches
b: 12 inches
c: 16 inches
d: 14 inches - CORRECT ANSWER -b: 12 inches
Refer: IMC Code 801.12


Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C)
comes under ________ combustible liquid:
a: Class I
b: Class II
c: Class IIIA
d: Class IIIB - CORRECT ANSWER -b: Class II

,Where located adjacent to walkways, the vertical termination of mechanical
draft systems shall be not less than ______ above the level of the walkway:
a: 7 feet
b: 5 feet
c: 3 feet
d: 4 feet - CORRECT ANSWER -a: 7 feet
Refer: IMC Code 804.3.5.1


Commercial kitchen Grease duct systems serving a Type I hood shall be
designed and installed to provide an air velocity within the duct system of not
less than ______ feet per minute:
a: 1000
b: 500
c: 400
d: 250 - CORRECT ANSWER -b: 500
Refer: IMC Code 506.3.4


The minimum openable area to the outdoors shall be ____ of the floor area
being naturally ventilated:
a: 6%
b: 8%
c: 4%
d: 2% - CORRECT ANSWER -c: 4%
Refer: IMC Code 504.7


Fire dampers are not required at penetrations of shafts where the steel exhaust
subducts extend at least _______ vertically in exhaust shafts provided that there
is a continuous airflow upward to the outdoors:

,a: 25 inches
b: 22 inches
c: 32 inches
d: 28 inches - CORRECT ANSWER -b: 22 inches
Refer: IMC Code 607.5.5 Exp 1.1


Underground Ducts shall have a minimum slope of _______ per foot to allow
drainage to a point provided with access:
a: 1/2 inch
b: 1/6 inch
c: 1/4 inch
d: 1/8 inch - CORRECT ANSWER -d: 1/8 inch
Refer: IMC Code 603.8.1


Masonry chimney flues shall be provided with a cleanout opening having a
minimum height of ______ :
a: 6 inches
b: 12 inches
c: 8 inches
d: 10 inches - CORRECT ANSWER -a: 6 inches
Refer: IMC Code 801.13


Commercial Kitchen Exhaust equipment serving a Type I hood shall have a
clearance to combustible construction of not less than ______ :
a: 30 inches
b: 12 inches
c: 24 inches
d: 18 inches - CORRECT ANSWER -d: 18 inches

, Refer: IMC Code 506.5.4


Steam-Heating Boiler operated at pressures not exceeding ______ for steam:
a: 20 psi
b: 15 psi
c: 10 psi
d: 25 psi - CORRECT ANSWER -b: 15 psi
Refer: IMC Code - Definitions


Commercial cloth dryer ducts shall have a minimum clearance of _____ to
combustible materials:
a: 9 inches
b: 12 inches
c: 8 inches
d: 6 inches - CORRECT ANSWER -d: 6 inches
Refer: IMC Code 504.7


The vent horizontal termination point for a mechanical draft system shall not be
located closer than _____ to an interior corner formed by two walls
perpendicular to each other.
a: 5 feet
b: 6 feet
c: 4 feet
d: 3 feet - CORRECT ANSWER -d: 3 feet
Refer: IMC Code 804.3.4.4


Breathing Zone region shall be more than _______ from the walls of the space
or from fixed air-conditioning equipment:
a: 3 feet

Written for

Institution
KY HVAC JOURNEYMAN 200
Course
KY HVAC JOURNEYMAN 200

Document information

Uploaded on
January 4, 2026
Number of pages
38
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$23.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
dukejosh116 Chamberlain School Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
17
Member since
7 months
Number of followers
1
Documents
1381
Last sold
4 days ago
ExamHackTutor

WELCOME TO EXAMHACKGURU — THE HOME OF POWERFUL, EXAM-READY STUDY GUIDES! I provide high-quality, exam-focused materials across NURSING, ATI, PMHNP, TNCC, USMLE PREP, WGU COURSES, ENGINEERING, SOCIOLOGY, BUSINESS, MATH, CALCULUS, THEOLOGY, PUBLIC POLICY, ANTHROPOLOGY, MILITARY, ARMY STUDIES, and many more subjects. Every guide is crafted with accuracy, clarity, and deep research to help you understand key concepts faster and prepare with total confidence. My resources are designed around essential exam topics and carefully reviewed to deliver reliable, A-level study support. Your success motivates me to keep producing the best academic materials—thank you for choosing EXAMHACKGURU!

Read more Read less
5.0

2 reviews

5
2
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions