FDNY Z51 RMO EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026/2027 the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the following, a more efficient centrifugal compressor operation results from - Answers lowering the condenser pressure In most semi hermetic compressors, the suction vapor is used for - Answers cools the motor The amount of refrigerant that flows through the orifices of an economizer is determined by the - Answers difference between the high side and the low side pressure the instalation of an inline refrigerant cleaning system is advisable - Answers to remove impurities from the system a refrigerant engineer verifies that a condenser pump is cavitation of the following the most likely cause for this condition is: - Answers a faulty cooling tower water level controller when an expansion valve is operating properly, at the end of the evaporator will contain - Answers only superheated vapor a centrifugal water pump is considered to be fully primed when - Answers the pump is full of liquid A refrigeration compressor has failed to turn on. the engineer on duty verifies the electrical circuit to the motor, including all switches and circuit breakers is complete, according to recomended service practice, the next item to be checked would likely be the: - Answers temperature and pressure controls Refrigerants are characterized by their physical properties including Flashpoint, refrigeration effect and others, of the refrigerants in commercial and industrial the highest latent heat and refrigerant effect is: - Answers ammonia which of the following ashrae refrigerant safety classification is the most toxic - Answers b3 which of the following ashrae refrigerant safety classification is the most flammable - Answers a3 in q indirect refrigeration system,of the following, the one that would not be used as a cooling medium for building spaces being cooled is - Answers r 22 (cooling medium= glycol or any brine solution) the primary way of achieving capacity control of a an centrifugal compressor is by: - Answers adjustment to the inlet impeller pre rotation vanes regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet low as possible - Answers keeps turbine blades wear to minimum a water chiller is equipped with a reciprocating compressor, a thermostatic expansion valve and a an air cooled condenser. A restriction in the refrigerant line would result in - Answers high suction super heat the process by which refrigerant is extracted and cleaned for reuse without requirements for reclamation is called - Answers recycle the purpose of wear rings in a centrifugal pump is to - Answers prevent wearing of the pump housing and impeller a centrifugal compressor is in operation with suction pressure is 3 psig and the discharge is 10psi what is the atmospheric pressure is 14.7 which is the ratio closest to - Answers 1.39 electrical current us measured in - Answers amperage how would you put an additional pump online - Answers open suction valve, open discharge valve gradually of the following, the major advantage of a shell and coil condenser is - Answers there is less danger of developing leaks an engineer needs to vary the flow of refrigerant in a refrigeration system, which operation in the flow of the system does not include - Answers solenoid valve thermal bull is attached to the suction plate between the evaporator cokl and the compressor by an insulated line. assume that the machine room is 85deg f . break down of the insulation results in: - Answers flood the evaporator water and moisture is serious problem in a refrigerant system how to avoid - Answers proper evaluation at the charging of the system while on duty a refrigeration engineer notic That the suction line to the compressor and part of the compressor itself is frosted over the following the most likely reason for this condition would be - Answers There is not enough Refrigerant in the system While doing a routine inspection the engineer notices the bulb of the TXV on the floor. The refrigerant engineer should have attached a bulb at the - Answers The outlet end of the coil A refrigerant engineer verifies that a chilled water pump is cavity to of the following the most likely cause for this condition is - Answers Water leaks through the mechanical seals The only refrigerant/temperature chart available to a refrigeration engineer lists the temperature In ゚C if the chart indicates a Celsius temperature of 4゚ this is equivalent to - Answers 39.2゚ The use of oil in the refrigeration machine is to - Answers Reduce wear and friction in the compressor parts Which of the following will connect to the Middle port on a gauge manifold - Answers Vacuum pump

Show more Read less
Institution
FDNY Z51 RMO
Course
FDNY Z51 RMO

Content preview

FDNY Z51 RMO EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026/2027

the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the
following, a more efficient centrifugal compressor operation results from - Answers lowering
the condenser pressure

In most semi hermetic compressors, the suction vapor is used for - Answers cools the motor

The amount of refrigerant that flows through the orifices of an economizer is determined by the
- Answers difference between the high side and the low side pressure

the instalation of an inline refrigerant cleaning system is advisable - Answers to remove
impurities from the system

a refrigerant engineer verifies that a condenser pump is cavitation of the following the most
likely cause for this condition is: - Answers a faulty cooling tower water level controller

when an expansion valve is operating properly, at the end of the evaporator will contain -
Answers only superheated vapor

a centrifugal water pump is considered to be fully primed when - Answers the pump is full of
liquid

A refrigeration compressor has failed to turn on. the engineer on duty verifies the electrical
circuit to the motor, including all switches and circuit breakers is complete, according to
recomended service practice, the next item to be checked would likely be the: - Answers
temperature and pressure controls

Refrigerants are characterized by their physical properties including Flashpoint, refrigeration
effect and others, of the refrigerants in commercial and industrial the highest latent heat and
refrigerant effect is: - Answers ammonia

which of the following ashrae refrigerant safety classification is the most toxic - Answers b3

which of the following ashrae refrigerant safety classification is the most flammable - Answers
a3

in q indirect refrigeration system,of the following, the one that would not be used as a cooling
medium for building spaces being cooled is - Answers r 22 (cooling medium= glycol or any brine
solution)

the primary way of achieving capacity control of a an centrifugal compressor is by: - Answers
adjustment to the inlet impeller pre rotation vanes

regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet low
as possible - Answers keeps turbine blades wear to minimum

, a water chiller is equipped with a reciprocating compressor, a thermostatic expansion valve and
a an air cooled condenser. A restriction in the refrigerant line would result in - Answers high
suction super heat

the process by which refrigerant is extracted and cleaned for reuse without requirements for
reclamation is called - Answers recycle

the purpose of wear rings in a centrifugal pump is to - Answers prevent wearing of the pump
housing and impeller

a centrifugal compressor is in operation with suction pressure is 3 psig and the discharge is
10psi what is the atmospheric pressure is 14.7 which is the ratio closest to - Answers 1.39

electrical current us measured in - Answers amperage

how would you put an additional pump online - Answers open suction valve, open discharge
valve gradually

of the following, the major advantage of a shell and coil condenser is - Answers there is less
danger of developing leaks

an engineer needs to vary the flow of refrigerant in a refrigeration system, which operation in the
flow of the system does not include - Answers solenoid valve

thermal bull is attached to the suction plate between the evaporator cokl and the compressor by
an insulated line. assume that the machine room is 85deg f . break down of the insulation
results in: - Answers flood the evaporator

water and moisture is serious problem in a refrigerant system how to avoid - Answers proper
evaluation at the charging of the system

while on duty a refrigeration engineer notic That the suction line to the compressor and part of
the compressor itself is frosted over the following the most likely reason for this condition
would be - Answers There is not enough Refrigerant in the system

While doing a routine inspection the engineer notices the bulb of the TXV on the floor. The
refrigerant engineer should have attached a bulb at the - Answers The outlet end of the coil

A refrigerant engineer verifies that a chilled water pump is cavity to of the following the most
likely cause for this condition is - Answers Water leaks through the mechanical seals

The only refrigerant/temperature chart available to a refrigeration engineer lists the temperature
゚ ゚
In C if the chart indicates a Celsius temperature of 4 this is equivalent to - Answers 39.2 ゚
The use of oil in the refrigeration machine is to - Answers Reduce wear and friction in the
compressor parts

Written for

Institution
FDNY Z51 RMO
Course
FDNY Z51 RMO

Document information

Uploaded on
January 7, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
441
Member since
1 year
Number of followers
16
Documents
31748
Last sold
2 days ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.5

73 reviews

5
26
4
16
3
14
2
1
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions