1. What is the primary purpose of grounding in an electrical system?
A) To reduce resistance in circuits
B) To provide a return path for current
C) To protect people and equipment from electrical faults
D) To increase voltage in the system
Rationale: Grounding provides a safe path for fault current to prevent
electric shock or equipment damage.
2. According to the Alberta Electrical Utility Code, the maximum
allowable voltage drop for feeders is:
A) 2%
B) 3%
C) 5%
D) 10%
Rationale: The code specifies a maximum 5% voltage drop to ensure
efficient operation of equipment and avoid overheating.
3. A type THHN wire is commonly used for:
A) Underground feeder only
B) Dry and wet locations inside conduits
, C) High-temperature outdoor service
D) Direct burial without conduit
Rationale: THHN is thermoplastic, heat-resistant, and suitable for dry and
wet locations when installed in conduit.
4. What is the minimum clear working space required in front of an
electrical panel rated 600V?
A) 0.6 m (2 ft)
B) 0.9 m (3 ft)
C) 1.0 m (3.3 ft)
D) 1.2 m (4 ft)
Rationale: The Alberta Electrical Code requires 1.2 m of clear space in
front of electrical equipment rated up to 600V for safe access.
5. Which overcurrent protection device is best suited for a motor with
high inrush current?
A) Standard fuse
B) Time-delay fuse
C) Circuit breaker without delay
D) Ground-fault breaker
Rationale: Time-delay fuses allow temporary inrush currents without
tripping, protecting motors from nuisance trips.
6. What is the function of a residual current device (RCD)?
A) To limit voltage drop
B) To detect leakage current and disconnect power
C) To increase circuit efficiency
D) To reduce harmonics
Rationale: RCDs (or GFCIs) quickly disconnect the supply if leakage
current is detected, preventing electric shock.
7. For a 3-phase, 4-wire system, which conductor carries the neutral
current?
A) Phase A
B) Phase B
, C) Phase C
D) Neutral conductor
Rationale: The neutral conductor carries the unbalanced current in a 3-
phase, 4-wire system.
8. What is the standard color code for grounding conductors in Alberta?
A) Red
B) Blue
C) Green or green with yellow stripe
D) White
Rationale: Grounding conductors are green or green/yellow to distinguish
them from current-carrying conductors.
9. Which material has the lowest electrical resistivity for conductors?
A) Aluminum
B) Copper
C) Iron
D) Brass
Rationale: Copper has lower resistivity than aluminum, iron, or brass,
making it more efficient for conductors.
10. When sizing conductors for continuous loads, the Alberta
Electrical Code requires:
A) 125% of the continuous load
B) 100% of the continuous load
C) 110% of the continuous load
D) 150% of the continuous load
Rationale: Continuous loads must be accommodated at 125% of full-load
current to prevent overheating.
11. What is the main purpose of bonding in electrical systems?
A) To increase current capacity
B) To reduce voltage drop
C) To ensure electrical continuity and fault protection
D) To prevent magnetic interference