Exam Questions and Answers:
Cranes idle for less than six months must have inspections
performed: -Answer:-Frequent ASME 3-2.1.5(a)
Cranes lifting personnel platform must have the platform and
rigging inspected: -Answer:-Prior to each shift ASME 3-
3.2.2(c)(1)
,Crane hooks must not be twisted in excess of: -Answer:-10
degrees OSHA 1910.180(d)(3)(v)
A Crane hooks throat open must not exceed -Answer:-15% of
its original size OSHA 1910.180(d)(3)(v)
By order of hitch strength which is the correct answer -
Answer:-Basket, Vertical, Choker
According to ASME B30.3 and OSHA you should always have at
least how many. wraps on a hoist drum -Answer:-2 ASME 3-
3.2.1(d)(7)
What is the minimum allowable distance from the crane and
power lines under 50kV -Answer:-10ft 3-3.4.3(1)
According to ASME B30.3, how many randomly broken wires
must there be to remove a running wire rope from serivce -
Answer:-12 ASME 3-3.4.3(b)(1)
, According to ASME B30.3 when working near power lines
when is a signal person required -Answer:-When crane moves
within a booms length of power lines ASME 3-3.4.3(a)(3)
According to OSHA after the crane has been checked out and
before personnel lift operations begin the crew should -
Answer:-Have a pre-lift meeting OSHA 1926.550(g)(8)
According to OSHA when is it safe to work closer than the
allowable distance from the power lines -Answer:-When utility
company says lines are de-energized OSHA 1926.550(a)(15)(vi)
When should a tagline be used -Answer:-When rotation of load
would be dangerous ASME 3-3.2.1(d)(8)
What is the minimum design factor required for a boom hoist
rope -Answer:-3.55 ASME 3-1.5.5(c)
How many broken wires must be present in one stand on one
lay for running wire rope to be removed from service -
Answer:-4 ASME 3-2.4.3(b)(1)