QUESTIONS WITH ANSWERS |\ |\
Electromagnetic Interference (5.5.5.5) - CORRECT |\ |\ |\ |\ |\
ANSWERS ✔✔caused when electromagnetic fields (radio
|\ |\ |\ |\ |\ |\
waves) induce high-frequency voltages in a wire or
|\ |\ |\ |\ |\ |\ |\ |\
component. (AC 43.13-1B 11-89) |\ |\ |\
Grounding (5.5.5.5) - CORRECT ANSWERS ✔✔Establishing
|\ |\ |\ |\ |\
a physical wire path that gives electricity a path to
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
earth/ground.
Bonding (5.5.5.5) - CORRECT ANSWERS ✔✔Connection of
|\ |\ |\ |\ |\ |\ |\
non-current carrying conductive elements ie. enclosures
|\ |\ |\ |\ |\ |\
and structures.|\
Conductor plating (5.5.5.1) - CORRECT ANSWERS |\ |\ |\ |\ |\ |\
✔✔Copper wire plated with Tin, Silver, or Nickel. Tin is the
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
most common. wire plating has a slower oxidation rate
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
than bare copper. |\ |\
Voltage drop in wires (5.5.5.1) - CORRECT ANSWERS
|\ |\ |\ |\ |\ |\ |\ |\
✔✔Should not exceed 2% of the regulated voltage when
|\ |\ |\ |\ |\ |\ |\ |\ |\
the generator is carrying rated current or the battery is
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
being discharged at 5 minute rate.
|\ |\ |\ |\ |\
, The allowable voltage drop in a 28 volt continuous circuit
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
is:
a. 1 volt
|\ |\ |\
b. 2 volts
|\ |\
c. 5 volts
|\ |\
d. 4 volts - CORRECT ANSWERS ✔✔a. 1 volt
|\ |\ |\ |\ |\ |\ |\ |\
Voltage rating (5.5.5.1) - CORRECT ANSWERS ✔✔The
|\ |\ |\ |\ |\ |\ |\
voltage rating of a cable is the highest voltage that may
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
be continuously applied to a completed cable
|\ |\ |\ |\ |\ |\ |\
construction in compliance with the relevant cable |\ |\ |\ |\ |\ |\ |\
standard or specification |\ |\
Shielded wire (5.5.5.1) - CORRECT ANSWERS ✔✔Electrical
|\ |\ |\ |\ |\ |\
wire that is enclosed in a braided metal jacket.
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
Electromagnetic energy radiated from the wire is trapped |\ |\ |\ |\ |\ |\ |\ |\
by the braid and is carried to ground.
|\ |\ |\ |\ |\ |\ |\
Receiving Inspection (5.4.1.1) - CORRECT ANSWERS |\ |\ |\ |\ |\ |\
✔✔ensure that incoming parts are checked against |\ |\ |\ |\ |\ |\ |\
purchase orders, manufacturers specifications, drawings
|\ |\ |\ |\ |\
and dimensions and other available documentation to
|\ |\ |\ |\ |\ |\ |\
CONFIRM AUTHENTICITY of the material. Conformance to
|\ |\ |\ |\ |\ |\ |\
applicable technical standards will be verified. Incoming
|\ |\ |\ |\ |\ |\ |\