Which duty is not the responsibility of a level I Inspector? Perform plans reviews.
A) Handle citizen complaints related to fire and life
safety.
B) Perform plans reviews.
C) Interpret and apply adopted codes and standards.
D) Determine occupancy loads for single-use buildings.
Most of the consensus standards that relate to fire and American National Standards Institute
life safety are developed by the following organizations
except:
ASTM International,
National Fire Protection Assoc.,
American National Standards Institute,
Underwriters Laboratories
Regarding Commercial Kitchen Hood Systems, pipe A liquid tight continuous external weld
penetrations of the exhaust hood require what?
a. Minimum 18 inch clearance to combustible materials
b. Printed manufacturer guidelines of spacing on the pipe
itself
c. Gas shut off valve and electrical shunt accessibility
d. A liquid tight continuous external weld
A independent, non-profit organization that tests Underwriters Laboratories Inc.
products for their intended use and certifies them as safe
describes:
A) ASTM International
B) American National Standards Institute
C) Underwriters Laboratories Inc.
D) Standards Council of Canada
,Which is not one of the three general types of drawings Aerial view
used to show structure, facility, or site information?
A. Plot plan
B. Aerial view
C. Floor plan
D. Elevation view
Structural lumber has a moisture content of ___________% or 19%
less.
25%
19%
15%
12%
Which of the following occupancies does not fall under Post office
state and local regulations?
A). Day care
B). Jail
C). Post office
D). Medical facility
The typical life cycle of a model code edition is ___ years. 3-5
a. 5-7
b. 2-3
c. 7-10
d. 3-5
For Dry systems exceeding 500 gallons, there must be a Not more than 60 seconds
quick opening device installed unless water is delivered
to the system test connection within a specific time frame.
What is this time frame?
A. 30 seconds
B. 60 seconds
C. Not more than 30 seconds
D. Not more than 60 seconds
Which of the following is an inspector not authorized to Prosecute an offender in a court of law.
do?
A. Issue a summons.
B. Issue citations.
C. File complaints for code violations.
D. Prosecute an offender in a court of law.
While exercising enforcement power, it is essential that Due Process
the inspector ensure that the rights of the accused are
protected and that ______________ is practiced.
A.) Worksite Safety
B.) Due Process
C.) Customer Appreciation
D.) Strict Compliance
, T or F Federal and some state/provincial-owned buildings False
located within the local jurisdiction are required to
comply with local codes.
An educational occupancy is any building or portion of a 6
building that is used for the purpose of education of ___ or
more persons from preschool through the 12th grade.
a. 6
b. 5
c. 10
d. 2
The term is used to describe a set of requirements similar Model Code
to a standard. A consensus organization, such as NFPA,
develop these codes that contain agreed-upon
requirements for such areas as fire and life safety designs
and installations.
A. Performance Code
B. Prescriptive Code
C. Model Code
D. Uniform Fire Code
The demolition of a structure is included in what New Construction
type/category of inspection?
A. Change of occupancy
B. Eminent hazard
C. New Construction
D. Response to a complaint
An inspector assembles all of the necessary tools and Thermal imagining camera
equipment and PPE that may be needed for an
inspection. Which of the following is NOT on the general
list of commonly used items for fire inspections:
A. Gloves
B. Safety shoes or boots
C. Thermal imagining camera
D. Flashlight
The lightly constructed panel doors or glass doors used Color coded designation
in general construction cannot act as barriers to high
temperatures developed in a fire. Which of the following
is NOT one of the three methods of classifying fire
doors?
A. Alphabetical letter designation
B. Color coded designation
C. Hourly fire-protection rating
D. Combination of hour and letter