The following measurements would be needed to properly
evaluate a complaint of "drafty" operation with a gas heating
system: ✓ ✓...... ANSWER ....... System TD,
Drop and static pressure
A furnace is inoperative because of a failure in the ignition
sequence at the flame proving stage. To check the flame
, Page 2 of 36
proving circuit the technician would: ✓ ✓...... ANSWER
....... Connect a microampmeter set to DC microamps in
the sensor circuit and operate the furnace.
A technician receives a call that a gas furnace is running
constantly in heating and cannot be shut off. While checking
the thermostat, the technician observes the burner shuts off
by removing the wire on the R terminal on the thermostat
subbase. ✓ ✓...... ANSWER ....... Most likely there is a
short in the thermostat subbase.
The continuity of a fuse should be tested by: ✓ ✓......
ANSWER ....... Checking resistance with power off.
A standing pilot furnace uses a relay for controlling the
supply blower. On a call for heat, the burner lights, the fan
control closes, but the blower does not run. A check of
voltage at the blower relay coil shows 24V. The load side
measures 0V. The technician should replace what: ✓ ✓......
ANSWER ....... Fan relay.
, Page 3 of 36
The following is true about fan run capacitors: ✓ ✓......
ANSWER ....... The fan capacitor shifts the electrical
phase angle.
The pressure switch on an induced draft blower system is
not closing properly; the technician can check the pressure
using a: ✓ ✓...... ANSWER ....... Bourdon tube pressure
gauge.
The blower access door is removed from a powered up gas
furnace with a door interlock switch. Assume the switch has
not been modified, the technician read across the door
interlock switch terminals should get: ✓ ✓...... ANSWER
....... Volts
A damaged section of double wall vent pipe is to be replaced
with a section produced by a different manufacturer: ✓
✓...... ANSWER ....... The installer should check the new
section for compatible locking joints.
If too much primary air is used the flame will: ✓ ✓......
ANSWER ....... Lift off the burner.
, Page 4 of 36
What is the problem when a flame on a high efficiency gas
furnace is burning primarily yellow: ✓ ✓...... ANSWER .......
The flame is burning without sufficient combustion air.
The cause of a voltage reading across a closed contact in a
24V control circuit is: ✓ ✓...... ANSWER ....... Pitted or
dirty contacts.
The following are the first two checks typically made on an
electronic control: ✓ ✓...... ANSWER ....... Presence of
any on board transformer voltage.
Proper output voltage.
During a service call on a unit the technician finds that the
wiring diagram is missing from the access panel. The
technician may begin troubleshooting by: ✓ ✓......
ANSWER ....... Tracing the circuits either mentally or on a
sketch pad.
The first check made for most electrical troubleshooting is a:
✓ ✓...... ANSWER ....... Voltage check of the supply line.