CBSPD CERTIFICATION EXAM 3 LATEST VERSIONS
(VERSION A, B AND C)||VERIFIED EXAM!!! NEWEST
2026 ACTUAL EXAM WITH COMPLETE QUESTIONS
AND CORRECT DETAILED ANSWERS (100%
VERIFIED ANSWERS) |ALREADY GRADED A+|
||NEWEST EXAM!!||
What is the starting point in sterilization? - Answer-
Cleaning
Define decontamination - Answer-The process of cleaning
surgical instruments, patient care devices, and all involved
surfaces in order to render areas and items safe for
handling and/or further processing
What are physical safety hazards? - Answer--good body
mechanics -correct body techniques and posture for lifting,
pushing, pulling, and reaching -should be alert and correct
anything that is a potential injury -lifts to lift heavy supplies,
available work material, adjustable chairs, padding on
sharp edges, correct height tables -proper clothing can
prevent injury
,2|Page
What is the weakest point of an instrument? - Answer-Box
lock and jaws
What does the ABC system stand for? - Answer-A: large
dollar amount items not used frequently
B: moderately priced and used frequently
C: items w/ low dollar value
What is just in time distribution? - Answer-Items are
distributed to department by vendor no need for sterile
storage or inventory control.
What should the sterilizer access area pressure be? -
Answer-Negative w/10 air exchanges per hour
What two steps are involved in decontamination? -
Answer-1. Manual and/or automated mechanical cleaning
2. application of a thermal or chemical disinfection process
Define Cleaning... - Answer-The removal of contamination
from an item to the extent necessary for further processing
or for the intended use.
, 3|Page
nosocomial infections are well documented and caused
by... - Answer-poor or ineffective decontamination of
instruments
What are Employee hazards in the decontamination
process? - Answer-Technicians work with a large amount
of 1) unidentified bioburden 2) wet enviornment 3)
handling contaminated sharps 4) must know procedures
for proper handling, equipment, cleaning/sterilization
agents
How do you properly clean a device? - Answer-follow the
device manufacturer's written instructions
What are specialty/ procedure carts? - Answer-Carts
placed in specific departments based on procedures
personalized to needs of departments easily accessible.
What is case cart distribution? - Answer-visually in
specialty areas case carts are delivered to department
case cart is specialized to departments needs