AMMO-69 EXAM QUESTIONS WITH 100% CORRECT
ANSWERS
Which of the following is not a responsibility of the qual/cert board chair?
Reviewing and signing training documentation
The (blank) is responsible for the commands qual...
CO
Which of the following is not a qual/cert chair responsibility?
Ensure the training manager updates the chair notebook
What's the minimum number of board members required to establish a qual/cert
program?
2
The records of personnel being cert must reflect the required training per the (blank).
Command training plan
Informal training (required reading and AE lectures). Must be documented usealizing a
standardized record sheet.
True
What must be completed before personnel can be in the Qual and CERT program?
All of the above
Which cert level can work unsupervised, but must have a TL in the general area?
Individual
Which is not a Qual CERT level?
In training
Which of the following is a permanent and does not allow for recertification?
Revocation
What is the work test code 6?
Testing
A complete list of ammunition and explosive documents instructions and directives can be
found in?
APPENDIX B OF THE NAVSEA OP-4
, The (blank) program provide guidance on the prevention of the accidental ignition of
electrically initiate a device is an ordinance due to radio frequency, electromagnetic fields.
HERO
Ordinance is most susceptible to earth environments during assembly disassembly,
handling, loading and unloading. Therefore ships must write and blank.
HERO EMCON Bill
SES, I should be conducted, at a minimum every (blank)
3 years
What is used as a source reference for the historical data of all weapons systems aboard the
ship for inspection, material readiness and operational documentation?
Smooth log
The magazine temperature record cards must be maintained for blank
1 year
A door Hatcher schedule should be closed 19 use unless it is blank
Interfering with operational requirements
All of the following apply to magazine, hatches, and doors, except blank
All magazine doors must open inword
Which of the following items cannot bestowed in a small arms locker?
20 mm CIWS rounds
The term "ready service" refers to a condition of ordinance that has been made ready
blank
For employment
Doesn't need smoking areas are forbidden within a (blank) of launchers, magazine areas,
handling, and loading areas of ready service lockers
10 feet
Portable battle lanterns are installed so that there is at a minimum of one to illuminate
each access closure and one to illuminate each passing scuttle one additional Lantern
should be provided for every blank sq feet
200
WP emergency protective equipment should always be stowed blank
In a separate storage locker outside the WP assembly area
ANSWERS
Which of the following is not a responsibility of the qual/cert board chair?
Reviewing and signing training documentation
The (blank) is responsible for the commands qual...
CO
Which of the following is not a qual/cert chair responsibility?
Ensure the training manager updates the chair notebook
What's the minimum number of board members required to establish a qual/cert
program?
2
The records of personnel being cert must reflect the required training per the (blank).
Command training plan
Informal training (required reading and AE lectures). Must be documented usealizing a
standardized record sheet.
True
What must be completed before personnel can be in the Qual and CERT program?
All of the above
Which cert level can work unsupervised, but must have a TL in the general area?
Individual
Which is not a Qual CERT level?
In training
Which of the following is a permanent and does not allow for recertification?
Revocation
What is the work test code 6?
Testing
A complete list of ammunition and explosive documents instructions and directives can be
found in?
APPENDIX B OF THE NAVSEA OP-4
, The (blank) program provide guidance on the prevention of the accidental ignition of
electrically initiate a device is an ordinance due to radio frequency, electromagnetic fields.
HERO
Ordinance is most susceptible to earth environments during assembly disassembly,
handling, loading and unloading. Therefore ships must write and blank.
HERO EMCON Bill
SES, I should be conducted, at a minimum every (blank)
3 years
What is used as a source reference for the historical data of all weapons systems aboard the
ship for inspection, material readiness and operational documentation?
Smooth log
The magazine temperature record cards must be maintained for blank
1 year
A door Hatcher schedule should be closed 19 use unless it is blank
Interfering with operational requirements
All of the following apply to magazine, hatches, and doors, except blank
All magazine doors must open inword
Which of the following items cannot bestowed in a small arms locker?
20 mm CIWS rounds
The term "ready service" refers to a condition of ordinance that has been made ready
blank
For employment
Doesn't need smoking areas are forbidden within a (blank) of launchers, magazine areas,
handling, and loading areas of ready service lockers
10 feet
Portable battle lanterns are installed so that there is at a minimum of one to illuminate
each access closure and one to illuminate each passing scuttle one additional Lantern
should be provided for every blank sq feet
200
WP emergency protective equipment should always be stowed blank
In a separate storage locker outside the WP assembly area