FIRE ALARM TECHNICAL EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026 If I defect is found when inspecting a fire alarm system, when shall the owner be notified in writing? - Answers Within 24 hrs When a software change is made to a fire alarm system, what percentage of the initiating devices not affected by the change must be tested? - Answers 10% Periodic testing records are required to be maintained for? - Answers One year after the next test A restorable heat detector must be tested with a heat source and respond within - Answers 1 minute A lead acid battery under load should not fall below _______ volts per cell. - Answers 2.05 What is the minimum time interval to replace a sealed lead acid battery? - Answers 5 years Visual inspection of batteries must include: - Answers A) check for corrosion B) tightness of connection C) cleaning of terminals if necessary D) electrolyte level is the battery is lead-acid The frequency of performing a visual inspection NiCad of batteries is? - Answers Semiannually When checking heat detectors with a heat source, a response is required within: - Answers 60 secs If you thought the insulation of one of the initiating device circuit conductors was damaged and the conductor had a path to ground, you could test it with a: - Answers Meggar How many tests are required when testing a combination smoke and CO detector? - Answers Two When load testing a NiCad battery there should be a minimum of ____ volts per cell. - Answers 1.42 A signal that continually repeat a two second tone every five seconds is a coded signal. - Answers False One of the primary requirements for using a pre-signal feature is: - Answers The signal goes to a continually manned supervising station A pre-signal station - Answers Only signals a supervised central location All manual fire alarm boxes shall be red in color - Answers True A manual fire alarm box that has a pen to pull and a glass rod to break before sending a signal is a _____? - Answers Dual action box A non-restorable heat detector: - Answers Must be replaced after actuating A bimetallic heat detector is an example of a ______. - Answers Restorable type Which of the following is not a spot type heat detector? - Answers Twisted Wire Which type of smoke detector is best for invisible smoke? - Answers Ionization A smoke detector that reflects light off of the smoke to a sensor uses the _______ design principle. - Answers Light scattering A projected beam sensor uses which of the following design principles? - Answers Light obscuration If the pressure of a wet type sprinkler system is monitored by a fire alarm system, the pressure setting should be plus or minus _____ psi of the nominal value. - Answers 10 Where monitoring of room temperature is required to detect freezing, what should the temperature setting be? - Answers 40 deg F A heat detector that contains a fusible link is what type of heat detector? - Answers Non-restorable What type of device must be marked with the response time index? - Answers Spot type heat detector A dry type sprinkler system that uses a pressure signal initiating device shall have a high and low supervisory signal activated at plus or minus _____ psi of the nominal pressure. - Answers 10 How long can smoke detector calibration tests be extended if they are still within calibration after the second test? - Answers 5 years

Meer zien Lees minder
Instelling
FIRE ALARM TECHNICAL
Vak
FIRE ALARM TECHNICAL

Voorbeeld van de inhoud

FIRE ALARM TECHNICAL EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026

If I defect is found when inspecting a fire alarm system, when shall the owner be notified in writing? -
Answers Within 24 hrs
When a software change is made to a fire alarm system, what percentage of the initiating devices not
affected by the change must be tested? - Answers 10%
Periodic testing records are required to be maintained for? - Answers One year after the next test
A restorable heat detector must be tested with a heat source and respond within - Answers 1 minute
A lead acid battery under load should not fall below _______ volts per cell. - Answers 2.05
What is the minimum time interval to replace a sealed lead acid battery? - Answers 5 years
Visual inspection of batteries must include: - Answers A) check for corrosion
B) tightness of connection
C) cleaning of terminals if necessary
D) electrolyte level is the battery is lead-acid
The frequency of performing a visual inspection NiCad of batteries is? - Answers Semiannually
When checking heat detectors with a heat source, a response is required within: - Answers 60 secs
If you thought the insulation of one of the initiating device circuit conductors was damaged and the
conductor had a path to ground, you could test it with a: - Answers Meggar
How many tests are required when testing a combination smoke and CO detector? - Answers Two
When load testing a NiCad battery there should be a minimum of ____ volts per cell. - Answers 1.42
A signal that continually repeat a two second tone every five seconds is a coded signal. - Answers
False
One of the primary requirements for using a pre-signal feature is: - Answers The signal goes to a
continually manned supervising station
A pre-signal station - Answers Only signals a supervised central location
All manual fire alarm boxes shall be red in color - Answers True
A manual fire alarm box that has a pen to pull and a glass rod to break before sending a signal is a
_____? - Answers Dual action box
A non-restorable heat detector: - Answers Must be replaced after actuating
A bimetallic heat detector is an example of a ______. - Answers Restorable type
Which of the following is not a spot type heat detector? - Answers Twisted Wire
Which type of smoke detector is best for invisible smoke? - Answers Ionization
A smoke detector that reflects light off of the smoke to a sensor uses the _______ design principle. -
Answers Light scattering
A projected beam sensor uses which of the following design principles? - Answers Light obscuration
If the pressure of a wet type sprinkler system is monitored by a fire alarm system, the pressure setting
should be plus or minus _____ psi of the nominal value. - Answers 10
Where monitoring of room temperature is required to detect freezing, what should the temperature
setting be? - Answers 40 deg F
A heat detector that contains a fusible link is what type of heat detector? - Answers Non-restorable
What type of device must be marked with the response time index? - Answers Spot type heat
detector
A dry type sprinkler system that uses a pressure signal initiating device shall have a high and low
supervisory signal activated at plus or minus _____ psi of the nominal pressure. - Answers 10
How long can smoke detector calibration tests be extended if they are still within calibration after the
second test? - Answers 5 years
What type of detector would be best suited for a two-story indoor shopping mall large public area? -
Answers Projected beam
A coded signal - Answers Gives information
A non-coded signal - Answers Conveys one discrete bit of information
A private signal - Answers Is generated at a supervisory station to allow investigation
A general alarm evacuation signal that sounds in the entire premises is a - Answers Public signal
A public mode audible signal shall have a sound level of at least ___ DBA above the average ambient
sound level or ____ DBA above the maximum sound level which ever is the greatest. - Answers 15, 5
And audible alarm appliance and the ambient sound level can never exceed - Answers 110 dbA
Audible appliances shall be mounted at least ______ inches above the floor if ceiling height permits -
Answers 90

Geschreven voor

Instelling
FIRE ALARM TECHNICAL
Vak
FIRE ALARM TECHNICAL

Documentinformatie

Geüpload op
2 februari 2026
Aantal pagina's
2
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
joshuawesonga22 Liberty University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
108
Lid sinds
1 jaar
Aantal volgers
1
Documenten
14595
Laatst verkocht
1 dag geleden
Tutor Wes

Hi there! I'm Tutor Wes, a dedicated tutor with a passion for sharing knowledge and helping others succeed academically. All my notes are carefully organized, detailed, and easy to understand. Whether you're preparing for exams, catching up on lectures, or looking for clear summaries, you'll find useful study materials here. Let’s succeed together!

3.5

11 beoordelingen

5
4
4
1
3
3
2
2
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen