Which of the following BEST determines the most advantageous position for an attack pumper?
a. size-up
b. mutual aid
c. experience of crew
d. time of day or night a. size-up
When fire conditions are evident upon arrival, the driver/operator should place the apparatus
in a safe position that: includes an exit route for apparatus should a withdrawal become
necessary
When the first apparatus arrives at an incident where no fire is evident, the driver/operator
should: pull apparatus past the front of the building
Which of the following is a guideline for positioning apparatus at a fire scene? attempt to
position apparatus upwind of incident
Which of the following is a method of protecting personnel from traffic at an incident? block
lanes of the road where firefighters are operating
When laying supply hose to the fire scene during a roadway response, lay the hose: to the
side of the street
What location is generally considered the safest position for apparatus placement should a
structural collapse occur? corners of the structure
Why do some jurisdictions require pumpers yield an optimum position close to a building for an
aerial apparatus? an aerial device, with its fixed length ladder or boom, is of no use
positioned beyond its maximum reach
, In the "inside/outside" method, when would an attack pumper be positioned on the side of the
street closest to the building and the aerial apparatus be placed outboard of the pumper? if
building is less than five floors tall
When positioning to support aerial apparatus, pumpers providing water supply for elevated
stream operations should position: as closely to aerial apparatus as practical
How is the pumper position to supply a fire department connection best determined? as
closely as possible to the water source
When should fire departments identify suitable drafting sites in their response district?
during preincident planning
When might tandem pumping operations may be needed? during the growth stages of a
fully involved building
What may be needed when driving the vehicle in conditions of reduced visibility during a
wildland fire attack? spotter walking ahead of the apparatus
Which of the following is a guideline for positioning for structure protection during clear
away any nearby brush that may serve as fuel
When the apparatus is operated in a stationary position during a wildland fire attack, it should
be placed in an area that: affords maximum protection from heat and flames
When positioning during wildland fire attack, the vehicle should be positioned facing the
direction of an exit path with the: front wheels straight
Solutions| Already Graded A+
Which of the following BEST determines the most advantageous position for an attack pumper?
a. size-up
b. mutual aid
c. experience of crew
d. time of day or night a. size-up
When fire conditions are evident upon arrival, the driver/operator should place the apparatus
in a safe position that: includes an exit route for apparatus should a withdrawal become
necessary
When the first apparatus arrives at an incident where no fire is evident, the driver/operator
should: pull apparatus past the front of the building
Which of the following is a guideline for positioning apparatus at a fire scene? attempt to
position apparatus upwind of incident
Which of the following is a method of protecting personnel from traffic at an incident? block
lanes of the road where firefighters are operating
When laying supply hose to the fire scene during a roadway response, lay the hose: to the
side of the street
What location is generally considered the safest position for apparatus placement should a
structural collapse occur? corners of the structure
Why do some jurisdictions require pumpers yield an optimum position close to a building for an
aerial apparatus? an aerial device, with its fixed length ladder or boom, is of no use
positioned beyond its maximum reach
, In the "inside/outside" method, when would an attack pumper be positioned on the side of the
street closest to the building and the aerial apparatus be placed outboard of the pumper? if
building is less than five floors tall
When positioning to support aerial apparatus, pumpers providing water supply for elevated
stream operations should position: as closely to aerial apparatus as practical
How is the pumper position to supply a fire department connection best determined? as
closely as possible to the water source
When should fire departments identify suitable drafting sites in their response district?
during preincident planning
When might tandem pumping operations may be needed? during the growth stages of a
fully involved building
What may be needed when driving the vehicle in conditions of reduced visibility during a
wildland fire attack? spotter walking ahead of the apparatus
Which of the following is a guideline for positioning for structure protection during clear
away any nearby brush that may serve as fuel
When the apparatus is operated in a stationary position during a wildland fire attack, it should
be placed in an area that: affords maximum protection from heat and flames
When positioning during wildland fire attack, the vehicle should be positioned facing the
direction of an exit path with the: front wheels straight