Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Oil Heat Exam|| QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||NEWEST EXAM!!

Beoordeling
-
Verkocht
-
Pagina's
37
Cijfer
A+
Geüpload op
03-02-2026
Geschreven in
2025/2026

Oil Heat Exam|| QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||NEWEST EXAM!!

Instelling
Oil Heat
Vak
Oil Heat

Voorbeeld van de inhoud

1|Page


Oil Heat Exam|| QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+||NEWEST EXAM!!
Combustion air obtained by means of ducts to outdoors
horizontally from two permanent openings one near top of
space one near bottom of space each opening total free
area of not less than - ANSWER-1 square inch per 2000
BTU's per hour


How to test OSV - ANSWER-Perform a vacuum test on oil
line and pump from just after OVS


What height does a power venter need to be over public
way - ANSWER-7ft


Combustion air obtained from freely communicating with
outdoor permanent openings total free area of not less
than - ANSWER-1 square inch per 5,000 btus per hour


Combustion air obtained from two permanent openings
one near top of space and one near bottom of space each
opening total free area of not less than - ANSWER-1
square inch per 1,000 BTU's per hour

,2|Page


Combustion air obtained by means of ducts to outdoors
vertically from two permanent openings one near top of
space one near bottom of space each opening total free
area of not less than - ANSWER-1 square inch per 4,000
BTU's per hour


The main source of air into a hydronic system is the -
ANSWER-Supply water


An automatic air bleed valve controls the airflow out of the
system by means of a - ANSWER-Float


Voltage of oil burner safely control circuit shall not exceed
- ANSWER-150 volts


What is the minimum thickness for a steel flue pipe up to 9
inch round - ANSWER-26 gauge


Can a manually operated draft damper be used in the
chimney connector - ANSWER-No


Can a chimney connector pass through or be hidden
behind a wall to connect to a chimney - ANSWER-No

,3|Page


what would cause pulsating oil pressure and fire -
ANSWER-defective fuel pump, defective burner motor,
defective burner coupling, air leaks in oil line, partially
clogged strainer or filter


what is the final product of burning hydrogen - ANSWER-
water vapor +nitrogen +heat


what is the final product of burning carbon - ANSWER-
carbon dioxide +nitrogen +heat


how do you test stack mounted primary control safety
timing - ANSWER-take heat sensing element out of flue
pipe, take #3 wire off stack switch, and shut oil off to
burner


a zero smoke and low co2 or higher 02 reading at the flue
pipe and over the fire is an indication - ANSWER-too much
air


expansion tanks must always be bled from the top of until
all of the hot air is removed from it - ANSWER-No

, 4|Page


it is possible for hydronic system with many zones to
operate with one circulating pump - ANSWER-yes


Hydronic heat circulators are centrifugal pumps. -
ANSWER-yes


in series loop the water going through the last terminal unit
will be the same temperature as the water through the first
unit - ANSWER-no


the only place a bleed valve is needed is on the top of the
boiler - ANSWER-no


a tank less domestic water system provides hot water from
a coil in the boiler - ANSWER-yes


FF on burner primary control is wired to - ANSWER-cad
cell


TT on the burner primary control is wired to - ANSWER-
thermostat


what is the amount of BTU'S in 1 gallon of No2 heating oil
- ANSWER-140,000 BTU'S

Geschreven voor

Instelling
Oil Heat
Vak
Oil Heat

Documentinformatie

Geüpload op
3 februari 2026
Aantal pagina's
37
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TrustedExams

Maak kennis met de verkoper

Seller avatar
TrustedExams Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
8
Lid sinds
5 maanden
Aantal volgers
0
Documenten
1474
Laatst verkocht
1 week geleden
EXCELLENT TUTOR

Welcome to my Stuvia store! I provide high-quality exam materials, including practice exams, past questions, and detailed solutions. All content is carefully prepared, accurate, and aligned with course requirements to help students revise effectively, boost confidence, and perform better in exams.

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen