15% (Percentages) - Answers Manufacturer's added stability factor (backward stability)
20% (Percentages) - Answers Gross capacity reduction on load chart for duty cycle operations
50% (Percentages) - Answers Load chart reduction for suspended personnel platform. 1926.1431
75% (Percentages) - Answers Stability factor on rubber & crawler cranes
85% (Percentages) - Answers Stability factor on outriggers
100% (Percentages) - Answers Gross capacity
110% (Percentages) - Answers Load testing
125% (Percentages) - Answers Man basket proof test weight for 5 minutes
Rotation Resistant Wire Rope (5:1 Safety Factor) - Answers 2 broken wires in one strand in 6 rope
diameters
Rotation Resistant Wire Rope (5:1 Safety Factor) - Answers 4 randomly broken wires in 30 rope
diameters (2 six packs at 4:30)
Rotation Resistant Wire Rope (5:1 Safety Factor) - Answers 1 broken wire from the core
Rotation Resistant Wire Rope (3.5:1 Safety Factor) - Answers Broken wire at an end connection
(standing rope i.e. pendant line)
Rotation Resistant Wire Rope (3.5:1 Safety Factor) - Answers Three wires randomly in one strand lay
length
Rotation Resistant Wire Rope (3.5:1 Safety Factor) - Answers Broken wires randomly in one lay length
Standing Ropes (Non-Rotation Resistant) (3:1 Safety Factor) - Answers 2 or more broken wires at an
end connection (standing rope i.e. pendant line)
Standing Ropes (Non-Rotation Resistant) (3:1 Safety Factor) - Answers 3 or more broken wires in 1 lay
length
Gross Capacity - Answers All the numbers on a load chart are Gross Capacities
Net Capacity - Answers Gross capacity minus all deductions
Gross Load - Answers Net load, plus rigging and all deductions
Net Load - Answers Weight of load that can be picked