All pneumatic line type heat detectors shall be tested for leak and
proper operations at six month intervals - ANSWER-True
ionisation smoke alarms with an alarm silencing switch so not be
installed less than____ horizontally from a permanently installed
cooking appliance - ANSWER-10 ft
Combination fire alarm systems may be interfaced with the -
ANSWER-Burglary system
Nurse call
Access control
non addressable (conventional) devices can be connected to an
addressable system by using a? - ANSWER-monitor module
All detectors receiving the required annual tests shall be tested by
means of - ANSWER-Aerosol not harmful to man
,2|Page
Diesel powered fire pumps must be monitored for all of the
following - ANSWER-Controller off
Engine running
Controller trouble
A presignal system shall not be installed unless approved by -
ANSWER-Fire Marshal
the ahj may require___ when information displayed on a
combination system annunciator is excessive. - ANSWER-two
separate displays
Smoke detectors may be installed in the airstream of supply ducts
- ANSWER-False
In one and two family dwelling units a smoke detector shall be
placed on each level, including the basement - ANSWER-True
,3|Page
What class circuit is considered to be a fail safe circuit -
ANSWER-D
What is the minimum required time for back up power to assume
the load during a power outage? - ANSWER-24 hours under
normal load, All devices for 5 minutes
which of the following would be found in a specification? -
ANSWER-intent (scope) of work, reference codes and standards,
patching and paint
What classifications are smoke detectors installed and used to
prevent the control of smoke spread by initiating controls of fans,
dampers, doors, etc. - ANSWER-A. Area smoke detectors
installed in rated smoke compartmentalization
B. Detectors installed in the duct system
The Mass Notification System (MNS) is intended to provide
emergency voice instructions in the event of - ANSWER-Fire
Terror Attack
, 4|Page
Tornado
Amber Alert
What is the type of system that signals to a municipal station -
ANSWER-A municipal fire alarm system
Define multiplexing - ANSWER-Where 2 or more signals may be
reversed or transmitted with identity
Define multiplexing - ANSWER-A signaling method
3.3.162
A(n)____ fire stopping material contains small amounts of water
that cools the penetration as it is burned. - ANSWER-ablative
In general, all smoke detectors shall be tested ______ -
ANSWER-Annually