AND SOLUTIONS SCORED A+
✔✔NFPA 1031 - ✔✔Standard for Professional Qualifications for Fire Inspector and Plan
Examiner
✔✔In a sprinkler system, water is distributed directly to branch lines by? - ✔✔Cross
mains
✔✔Who provides contact and logistical information on the plans review application? -
✔✔The applicant for the plans review
✔✔FM-200 - ✔✔Clean agent
✔✔When on-scene to investigate a complaint: - ✔✔1. Bring facility folder
2. take detailed notes
3. ensure correction is initiated before leaving
4. if situation requires work order, ensure the work order is completed.
✔✔NFPA technical committee - ✔✔share information for a recommendation, comment
or proposal for code modification through mail, fax, or electronic format.
✔✔Places where inspectors can find an NFPA Technical Committee Document
Proposal Form: - ✔✔1. www.nfpa.org
2. at the end of NFPA 10
✔✔A proposal to modify an existing NFPA code must: - ✔✔receive approval by 2/3
majority of committee members
✔✔Areas of knowledge a fire inspector must possess in order to make
recommendations that can change policies or procedures. - ✔✔1. resolving conflicts
2. decision making
3. conducting research
✔✔who is responsible for the SOP - ✔✔the assistant chief for fire prevention shall
mange the fire company inspection program to ensure quality control.
✔✔Purpose of the SOP - ✔✔establishes to procedures for fire companies to follow
when conducting annual facility inspections.
✔✔factor that may negatively affect your time management skills - ✔✔interruptions
✔✔one way to raise the level of fire prevention awareness in your community is to: -
✔✔conduct community educational programs
, ✔✔what should a fire inspector take if the conditions of the permit are not met by the
permit applicant? - ✔✔revoke the permit
✔✔plans review applications - ✔✔vary from jurisdiction to jurisdiction
✔✔Three critical elements that the fire inspector must validate during an inspection: -
✔✔1. Fire department emergency access
2. Fire exit drills
3. Emergency evacuation plans
✔✔Site Plan - ✔✔a view of the building as seen from directly above. Shows roof of
building, surrounding yards, walks driveways and other features within the property line.
Usually shows the streets and property immediately adjacent to the site.
✔✔A fire lane must have an unobstructed width of: - ✔✔20 feet
✔✔NFPA 1 requires what of buildings that are 150' away from a paved road? - ✔✔fire
department access roads or fire lanes be provided.
✔✔When is a cul-de-sac turnaround required? - ✔✔road is a dead end and exceeds
150'
✔✔What facilities must provide suitable all-weather ground access surface for aerial
apparatus on a minimum of two sides? - ✔✔New facilities four stories or more in height
and all new warehouses
✔✔A building 5000 sq ft or more than two stories must have: - ✔✔at least one means of
all-weather ground access.
✔✔All emergency evacuation plans should have three basic components: - ✔✔1.
Evacuation routes
2. Monitor duties
3. Employee duties
✔✔How often must fire exit drills be conducted? - ✔✔depends on the specific
occupancy
✔✔Assembly occupancies - ✔✔used for gathering 50 or more persons
✔✔special amusement building classification - ✔✔classified as an assembly
classification even though they don't meet the 50 person rule