Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

BACKFLOW PRACTICE EXAM QUESTIONS & SOLUTIONS(RATED A+)

Beoordeling
-
Verkocht
-
Pagina's
7
Cijfer
A+
Geüpload op
12-02-2026
Geschreven in
2025/2026

1) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: - ANSWERC. Public water system or consumer's portable water system 2) An approved airgap (AG) is a physical separation between the free-flowing end of a: - ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 3) And indirect cross-connection is one that is subject

Meer zien Lees minder
Instelling
Backflow Certification
Vak
Backflow certification

Voorbeeld van de inhoud

BACKFLOW PRACTICE EXAM
QUESTIONS & SOLUTIONS(RATED
A+)
1) Backflow is the undesirable reversal of flow of water or other substances through a
cross connection into the public water system or consumer's: - ANSWERC. Public water
system or consumer's portable water system

2) An approved airgap (AG) is a physical separation between the free-flowing end of a: -
ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-
pressurized receiving vessel

3) And indirect cross-connection is one that is subject to what type of backflow? -
ANSWERA. Only backsiphonage

4 )Cross-connections with between the portable water piping in any piping or containers
containing substances not approved as potable water must be either eliminated or
controlled by the installation of an: - ANSWERD. Approved air gap or an approved
backflow prevention assembly

5) While testing CV #2 of a DCVA if CV #2 leaks the BAT would observe that the water
flow: - ANSWERD. Stops from the site tube at TC#4 and no differential shows on the
gauge

6) Service protection is a way to protect a public water system from contamination due
to back flow from the customer's water system by the installing an approved backflow
preventer at the: - ANSWERA. Service connection which is considered to be at or near
the water meter

7) A Washington state certified Backflow Assembly Tester is certified to: - ANSWERD.
Inspect, test and monitor backflow prevention assemblies

8) The RPBA is designed so that if the check valve leaks, the relief with valve may: -
ANSWERB. Open to discharge through the relief valve vent

9) An AG installed in lieu of an approved backflow prevention assembly must be
inspected for compliance with the definition of an improved air gap by: - ANSWERC.
Either a CCS or a BAT

10) After testing an approved backflow prevention assembly the BAT shall complete a
test report that is acceptable to the: - ANSWERC. Purveyor

11) The gauge on a differential pressure test kit indicates: - ANSWERC. psid

, 12) Loading a check valve with springs or weights: - ANSWERC. Reduces pressure
down stream of the check valve

13) If there is flow across CV#1 and through an RPBA the relief valve will not discharge
unless: - ANSWERC. The relief valve is defective

14) Microbiological contaminates entering the portible water system are always a: -
ANSWERA. High-health standard

15) All approved backflow prevention assemblies must be tested with a: - ANSWERD.
Differential pressure test kit

16) An approved backflow prevention assembly is an: - ANSWERC. RPBA, RPDA,
DCVA, DCDA, PVBA, or SVBA of make, model, and size that is approved by the DOH

17) Permanent support blocks are required under all approved backflow assemblies that
are: - ANSWERD. A large size assembly

18) A backflow assembly test report must be: - ANSWERC. Complete, accurate and
legible

19) SOV #1 of a properly installed PVBA
is reported as leaking while testing the air inlet valve if water continues to flow from: -
ANSWERC. The high-bleed valve and the differential gauge does not drop to the
opening point of the Air Inlet Valve

20) The differential pressure relief valve must discharge water to the atmosphere when
the pressure in the zone between the check valves is with in: - ANSWERB. 2 psi of the
pressure upstream of CV #1

21) The Undesirable reversal of flow of water or other substances through a cross
connection into the public water system or consumers potible water system is: -
ANSWERD. Backflow

22) While testing CV#2 of an RPBA the BAT must determine if CV#2 closes tight: -
ANSWERD. In the reverse direction of flow

23) A DCDA should not be installed: - ANSWERB. Where pressure in the water system
is greater than the assembly's maximum working water pressure

24) The contents of the backflow assembly test report completed after testing a
backflow prevention assembly installed at the water meter must meet the requirements
of the: - ANSWERD. Water purveyor

Geschreven voor

Instelling
Backflow certification
Vak
Backflow certification

Documentinformatie

Geüpload op
12 februari 2026
Aantal pagina's
7
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
shantelleG West Virgina University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
641
Lid sinds
3 jaar
Aantal volgers
369
Documenten
18264
Laatst verkocht
5 dagen geleden
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 beoordelingen

5
69
4
11
3
24
2
2
1
12

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen