MAGNETIC RESONANCE SAFETY OFFICER (MRSO) EXAM
PREPARATION NEWEST WITH COMPLETE QUESTIONS AND
CORRECT DETAILED ANSWERS| BRAND NEW VERSION


How do magnetic flux lines travel?

A. North to South

B. South to North

C. East to West

D. West to East - CORRECT ANSWERS-A North to South



What is the difference between a shielded MR unit and an MR unit that is not shielded?

A. It will make the magnetic spatial gradient more uniform.

B. The magnetic spatial gradient is more confined to the MR unit.

C. It will cause the effects of translational force to be experienced further away from the MR unit.

D. It will push the 5 G line closer to the entrance of zone IV. - CORRECT ANSWERS-B. The
magnetic spatial gradient is more confined to the MR unit.



Which of the following will not exaggerate an artifact on an MR brain scan?

A. A brain aneurysm clip

B. ferrous foreign body in their skull

C. non-ferrous earrings. - CORRECT ANSWERS-C. non-ferrous earrings.



Which of the following can be used to reduce artifacts in the image?

A. Decrease receiver bandwidth.

B. Use a GRASS pulse sequence.

C. Decreasing the image matrix.

D. Running a PD sequence rather than a T2. - CORRECT ANSWERS-D. Running a PD sequence
rather than a T2.



Which of the following organizations help conduct research and produce regulations?

,A. IEC

B. FDA

C. ASTM

D. All of the choices. - CORRECT ANSWERS-D. All of the choices.



Which of the following are conditions that will make an object MR safe?

A. Non-metallic

B. Non-magnetic

C. Non-conductive

D. All of the choices - CORRECT ANSWERS-D. All of the choices.



Which of the following modes will limit the SAR to the head to 3.2W/kg?

A. Normal mode..

B. First Level Controlled Mode.

C. Second Level Controlled Mode.

D. Normal and First Level Controlled Mode. - CORRECT ANSWERS-D. Normal and First Level
Controlled Mode.



The Main focus of the ICNIRP in MRI is what?

A. Radiation dose.

B. Occupational dose. - CORRECT ANSWERS-B. Occupational dose.



The FDA performs research and testing.

A. True

B. False - CORRECT ANSWERS-B. False



Which of the following would most likely be considered a Level 1 MR Personnel?

A. MR Technologist

B. Radiologist

,C. Someone who has not received MR Safety training in 1 year.

D. Tech aid - CORRECT ANSWERS-D. Tech aid



We would find a patient changing into a gown in what zone?

A. Zone I

B. Zone II

C. Zone III

D. Zone IV - CORRECT ANSWERS-B. Zone II



NEMA will perform testing on materials

A. True

B. False - CORRECT ANSWERS-A. True



A herrington rod is an example of what?

A. Passive implant.

B. Active implant.

C. Both - CORRECT ANSWERS-A. Passive implant.



The greatest chance of a burn to a patient comes from which of the following?

A. Static magnetic field.

B. Time-varying gradient magnetic field.

C. Time-varying radiofrequency field. - CORRECT ANSWERS-C. Time-varying radiofrequency
field.



Which of the following can be potential safety concerns to a patient in the static magnetic field?

A. Electrically conductive materials

B. Ferrous objects

C. Magnetic objects

D. All of the choices. - CORRECT ANSWERS-D. All of the choices

, An object that retains its magnetic field when exiting the static magnetic field is call what?

A. Paramagnetic

B. Diamagnetic

C. Ferromagnetic

D. Superparamagnetic - CORRECT ANSWERS-C. Ferromagnetic



What direction is the vector of a permanent MR unit?

A. Horizontal

B. Vertical

C. Diagonal

D. Variable - CORRECT ANSWERS-B. Vertical



What separates a superconducting MR unit from a resistive MR unit?

A. Cryogen

B. Coils of wires

C. Permanent magnets

D. none of the choices - CORRECT ANSWERS-A. Cryogen



The increasing strength of magnetism as we move closer to the MR unit is called what?

A. Ferromagnetism

B. Spatial magnetic gradient field

C. Vector

D. B0 - CORRECT ANSWERS-B. Spatial magnetic gradient field



What is responsible for attracting ferrous objects into the MR unit?

A. Spatial magnetic gradient fields

B. Strong uniform magnetic fields

C. Gradient coils

Geschreven voor

Vak

Documentinformatie

Geüpload op
15 februari 2026
Aantal pagina's
32
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$24.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
september10

Maak kennis met de verkoper

Seller avatar
september10 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
1 jaar
Aantal volgers
0
Documenten
712
Laatst verkocht
1 maand geleden
september 10

AFTER MULTIPLE TONES OF RESEARCH THE MAIN AIM IS TO OFFER NOTHING BUT THE BEST FOR THE LEANERS IN A WORLD WHERE WISDOM IS VALUED THESE TESTS ARE A CONFIRMATION OF SUCCESS.THE RESOURSES ARE THOUGHTFULLY PREPARED TO SUPPORT YOU LEARNING JOURNEY AND MAKE YOUR STUDIES AND EXAM PREPARATION SMOOTH AND EFFECTIVE.

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen