1. What are the classifications of Fire Extinguisher? - ANSWER ✔ A: Wood
and cloth B: Flammable liquids
C: Electrical Equipment D: Metallic Fires
K: Kitchen fires
2. How often do electrically rated gloves need to be tested - ANSWER ✔
before issue and every 6 months after, 1 upon indication that insulating value
is suspect; after repair; and after use without protectors. if they have been
tested but not issued then every 12 months
3. What are the two types of rubber gloves? - ANSWER ✔ Type 1: not ozone
resistant
Type 2: ozone resistant
4. When should hard hats be worn? - ANSWER ✔ when working in areas
where there is a potential for injury to the head from falling objects or
conductors.
,5. What are the different classes of hard hat? - ANSWER ✔ E-electrically
rated. (20,000) Hi volt
G-General purpose. (2,200) low volt
C-Conductive no protection
6. When do hardhats need to be replaced? - ANSWER ✔ when there is visual
damage
7. What are the types of hard hat - ANSWER ✔ Type 1-impacts from above
Type 2-impacts from above and laterally
8. clothing with what type of materials are considered not fire resistant. -
ANSWER ✔ Synthetic materials
9. When is fall protection required? - ANSWER ✔ any fall that is 6ft or higher
10.employers must ensure that employees are safe from falls with what kinds of
equipment. - ANSWER ✔ Guard rails safety nets or personal fall protection
equipmet
11.what is proper ladder climbing technique?? - ANSWER ✔ face the ladder,
using at least one hand firmly grasp the ladder, do not carry any load that
would cause imbalance.
12.rungs and steps on ladders must be what when the ladder is in position for
use - ANSWER ✔ parallel, level and uniform
, 13.What is the maximum acceptable leakage current for electrical shock
resistant (EH) footwear under dry conditions - ANSWER ✔ 1ma
14.A properly fitted balaclava should be tight against the head to increase the
arc rating. - ANSWER ✔ F
15.Which NFPA standard provides safe work procedures? - ANSWER ✔ 70E
16.A given battery bank feeding a 240V UPS system has an available fault
current of 5kA and a maximum arc duration of 2 seconds. According to
NFPA 70E, which of the following would be considered an acceptable Arc-
Flash Boundary for this equipment? - ANSWER ✔ 72in
17.Which ANSI standard covers safety requirements for industrial head
protection? - ANSWER ✔ ANZI 89.1
18.Class 4 rubber insulating gloves are proof tested at 40,000 VAC, what is the
AC max use voltage of these gloves? - ANSWER ✔ 36000
19.What are the acceptable oxygen levels for a confined space? - ANSWER ✔
19.5-23.5
20.. Which organization sets the primary safety standard for arc flash protective
clothing in the United States? - ANSWER ✔ ATSM
21.At what current level does ventricular fibrillation occur? - ANSWER ✔ 100-
200MA