QUESTIONS WITH ANSWERS GRADED A+
◉ XO responsibilities in DC CoC. Answer: - Keeps CO advised of ship
readiness status
- Commands the Damage Control Training Team (DCTT)
- Gives final approval of DCPO's
- Heads the planning board for PB4T
◉ Damage Control Assistant Responsibilities in DC CoC. Answer: -
Submits all-hands training schedule to PB4T
- Informs DCO of changes to DC equipment status
- Oversees training and qualifications of repair lockers and Damage
Control Central (DCC) personnel
- Supervises training of all DCPOs
◉ Division Officers Responsibility in DC CoC. Answer: - Assign people
to DC organizations on bills
- Recommends a DCPO to the Dept Head
- Assigns DCPQs )Personnel Qualification Standards)
◉ DCPO's responsibility in DC CoC. Answer: - Maintain DC duties as
primary responsibilities
,- Conduct all PMS on portable DC equipment in divisional spaces
- Supervise daily setting of specified material conditions within
divisional spaces
◉ Which team in DC dresses out fully? Answer: The Attack Team
◉ Repair Locker numbers. Answer: Repair 3 (AFT)
Repair 5 (Eng)
Repair 2 (FWD)
◉ Components of Firefighting Ensemble. Answer: - Helmet
- Flash Hoos
- Fire Protective Gear
- Gloves
- Boots
- SCBA
◉ SCBA Sizes. Answer: 30 and 45 minutes
◉ What does EEBD Stand for. Answer: Emergency Escape Breathing
Device
,◉ What are the colors of the EEBD? Answer: Actual: Orange
Training: Blue
◉ What are the requirements to ensure the EEBD is in working
condition? Answer: - Needle is in the green
- The tamper is not broken
- The EEBD is not expired
◉ Berthing requirements for EEBD. Answer: 100% of personnel
◉ How much time does an EEBD have? Answer: 10 minutes
◉ CO2 Portable Firefighting Equipment Information. Answer: - Class C
Fires
- Size: 15 lbs
- How it extinguishes fire: Displaces oxygen
- Discharge time: 35-40 seconds
- Range: 4-6 ft
◉ AFFF Portable Firefighting Equipment. Answer: - Class B Fires
- Size: 28 lbs
- How it extinguishes fire: Creates a vapor barrier and cools
, - Discharge time: 45-65 seconds
- Range: 10 ft and decreasing
◉ Purple K Powder (PKP). Answer: - Class B Fires
- Size: 18/27 lbs
- How it extinguishes fire: Breaks up the combustion chain reaction
- Discharge time: 10/11 seconds
- Range: 19/21 ft
◉ Types of Patches for pipe bursts. Answer: - Jubilee
- EWARP
- Soft Patch
◉ Restrictions of a Jubilee patch. Answer: - Used for systems with 100
psi or less
- Gasket material must extend 2 in past on both sides
◉ Restrictions of an Emergency Water Activated Repair Patch
(EWARP). Answer: - Used for systems with 150 psi or less
- System does not exceed 300F
- Can not be used on fuel or potable water systems