When do the Texas Accessibility Standards apply?
During the design, construction, additions to, and alterations of site,
facilities,
buildings, and elements to the extent required by regulations issued by the
Texas Department of Licensing and Regulation under the authority of
Texas
Government Code, Chapter 469.
What is a Residential Dwelling Unit?
A unit intended to be used as a residence that is primarily long-term in
nature.
What are some dwellings that are NOT Residential Dwelling Units?
Residential dwelling units do not include transient lodging, inpatient
medical care, licensed long-term care, and detention or correctional
facilities.
,What is the definition of "Technically Infeasible"?
With respect to an alteration of a building or a facility, something that
has little likelihood of being accomplished because existing structural
conditions would require removing or altering a load-bearing member
that is an essential part of the structural frame; or because other
existing physical or site constraints
prohibit modification or addition of elements, spaces, or features that
are in full and strict compliance with the minimum requirements.
How is infeasibility determined?
All determinations of technical infeasibility are made by the Department in
accordance with the variance procedures contained in Chapter 68, Texas
Administrative Code.
Transient Lodging
A building or facility containing one or more guest rooms for sleeping that
provides accommodation that are primarily short term in nature. (i.e.,
hotels and motels)
No fewer than ___ drinking fountains shall be provided.
two
,One drinking fountain shall comply with and one drinking fountain shall
comply with _______
602.1 through 602.6 , 602.7 (Hi-Lo, one fountain for seated persons and
one fountain for standing persons)
Where more than the minumum number of drinking fountains are provided
______________.
50 percent shall comply with 602.1 through 602.6, and 50 percent shall
comply with 602.7 (Hi-Lo, 50 percent for standing persons and 50
percent for seated persons)
Unisex toilet rooms shall contain not more than ____________
one lavatory, and two water closets without urinals or one water closet
and one urinal.
Doors to unisex toilet rooms and unisex bathing rooms shall have _______
privacy latches.
Toe clearance shall be considered:
space between the finished floor and 9 inches above the finished floor
Toe clearance depth shall be between:
17 and 25 inches.
, Toe clearance width shall be
30 inches, minimum.
Knee clearance shall be considered:
Space under and element between 9 inches and 27 inches above the
finished floor.
Knee clearance depth shall be:
11-25 inches at 9 inches high, 8-25 inches at 27 inches high, reducing 1 inch in
clearance for every 6 inches in height.
Knee clearance depth shall be:
30 inches wide, minumum.
Spout outlets shall be ______above the finished floor.
36 inches maximum
For seated persons, drinking fountain spout shall be located
36 inches maximum above finished floor.