This document serves as a specialized study resource for individuals preparing for the Master Plumbing Certification Exam. It contains a series of rigorous, industry-standard questions and verified answers covering critical plumbing codes, installation procedures, and safety regulations. Key topics include: Testing and Inspection: Requirements for building sewers, DWV systems, and water piping, including specific pressure levels and duration. +2 System Design and Dimensions: Clearance requirements for cleanouts, water closets, and urinals, as well as trap arm distances and water seal depths. +4 Piping and Materials: Standards for PEX, copper (Type DWV), and nonferrous piping, including support intervals and burial depths. +3

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

THE MASTER PLUMBING CERTIFICATION EXAM A+
PASS WITH BEST QUESTIONS AND
ANSWERS.LATEST

Building sewers shall be tested by completely filling the sewer with water from the
______
A. Lowest to highest point
B. Lowest to at least 5' head
C. Lowest to at least 10' head
D. Lowest to at least ground level - ANSWER-C. Lowest to at least 10' head

Hot and cold water piping may be tested with ____
A. 40 psi-150 psi water for 10 minutes
B. 35 psi for at least 15 minutes
C. 50 psi or the working pressure of the water in the system for at least 15 minutes
D. 100 psi of air for at least 10 minutes - ANSWER-C. 50 psi or the working pressure
of the water in the system for at least 15 minutes

The required clearance in front of a 3" cleanout is ____
A. 12"
B. 18"
C. 24"
D. 36" - ANSWER-B. 18"

A stack as defined in the code is ____
A. Main vent
B. Any vertical vent
C. The vertical main of a soil, waste, or vent piping which extends one or stories
D. Horizontal main of a soil, waste, or vent stack - ANSWER-C. The vertical main of
a soil, waste, or vent piping which extends one or stories

Above ground PEX piping installed horizontally shall be supported at intervals not to
exceed _________.
A. Depends on the pipe size
B. 24"
C. 32"
D. 36" - ANSWER-C. 32"

The minimum vertical length for a gravity type venting system serving a fuel fired
water hear is _________.
A. 4'
B. 5'
C. 10'

,D. Based on the Btu rating - ANSWER-B. 5'

The maximum horizontal distance of a trap arm is measure from the inner edge of
the vent to the _____
A. Weir of the trap
B. Dip of the rap
C. Inlet of the trap
D. None of the above - ANSWER-A. Weir of the trap

Sleeves shall be provided to protect piping ____
A. Passing through floors or concrete walls
B. Passing through concrete and masonry walls
C. Passing through wood or concrete walls
D. Passing through all locations listed above - ANSWER-B. Passing through concrete
and masonry walls

The drain connecting the compartments of a set of fixtures to its trap is called a/an
_____
A. Continuous waste
B. Combination waste and vent
C. Indirect waste
D. None of the above - ANSWER-A. Continuous waste

A device to prevent backflow in to the potable water system is called a _____
A. Backflow connection
B. Backflow preventer
C. Backwater preventer
D. Both A and B - ANSWER-B. Backflow preventer

Copper tube and fittings used for drainage and vent piping installed above ground
shall be at least ________
A. Type L
B. Type M
C. Type K
D. Type DWV - ANSWER-D. Type DWV

All trenches deeper than the footing of any building or structure and paralleling the
same must be at least _____
A. 45 degrees therefrom
B. 4' therefrom
C. 2' therefrom
D. 90 degrees thereform - ANSWER-A. 45 degree therefrom

The minimum size trap and trap arm for a kitchen sink is _______
A. 1.5 inches
B. 2 inches

, C. 1 1/4 inches
D. Either A or B - ANSWER-A. 1.5 inches

Horizontal drainage liens connecting with other horizontal drainage lines shall enter
through __________
A. 45 degrees wye branches
B. Sanitary tee branches
C. 1/4 bend with end outlet
D. Side inlet sweep - ANSWER-A. 45 degrees wye branches

For each run of horizontal drain piping, the distance between cleanouts shall not
exceed ____
A. 50'
B. 75'
C. 100'
D. None of the above - ANSWER-C. 100'

A plumbing vent shall terminate no less than ____
A. 3' from an air intake
B. 10' from an air intake
C. 1' above the roof
D. 3' above a parapet wall - ANSWER-B. 10' from an air intake

Each drainage stack which extends 10 or more stores above the building drain shall
be served by _____
A. Cleanouts
B. A parallel vent stack
C. A parallel stack vent
D. Straps every 10 feet - ANSWER-B. A parallel vent stack

Chemical or industrial liquid wastes which are likely to damage th public sanitary
sewer system shall _______
A. Be drained into a holding tank
B. Not be used under any conditions
C. Pretreated to render them innocuous
D. Be drained into a storm drain - ANSWER-C. Pretreated to render them innocuous

Special venting for island fixtures is used for ______
A. Bathtubs
B. Showers
C. Kitchen sinks
D. Washing machines - ANSWER-C. Kitchen sinks

The vertical distance between a fixture outlet and the trap weir shall not exceed ____
A. 12"
B. 18"

Geschreven voor

Vak

Documentinformatie

Geüpload op
17 februari 2026
Aantal pagina's
22
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$34.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
preptestexam

Maak kennis met de verkoper

Seller avatar
preptestexam Chamberlian School of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
2 jaar
Aantal volgers
0
Documenten
61
Laatst verkocht
-

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen