◉ Churning. Answer: A condition in a centrifugal in which the
impeller is rotating, but no water is being discharged.
◉ Combination Standpipe and Sprinkler System. Answer: A system
where the water piping service both 2 1/2in (65) outlet for fire
Department use and oulet for automatic sprinkler
◉ Concealed Sprinkler. Answer: A recessed sprinkler with a cover
plate
◉ Deluge Valve. Answer: water supply control valve intended to be
operated by actuation of an automatic detection system that is
installed in the same area as the discharge devices. Suitable for
HAZARDOUS OCCUPANCIES. INTENDED USE IS MANUAL AND AUTO
◉ Deludge Sprinkler System. Answer: A sprinkler system employing
open sprinklers that are attached to a piping system that is
connected to a water supply through a VALVE that is opened of a
DETECTION SYSTEM installed in the same area as the sprinklers
,◉ Dry Pipe Sprinkler System. Answer: A sprinkler system employing
automatic sprinklers that are attached to a piping system containing
air or nitrogen under pressure. The release of the air or nitrogen,(as
from the opening of a sprinkler) results in the water pressure
opening a valve known as a dry pipe valve, resulting in the flow of
water into the piping system and out of the fused sprinklers heads.
◉ Dry Sprinkler. Answer: A sprinkler secured in an extension nipple
that has a seal at the inlet to prevent water from entering the nipple
until the sprinkler operates. May be configured with an upright,
pendent or sidewall sprinkler. AUTO/NON_AUTO
◉ Dry Standpipe. Answer: A standpipe system designed to have
piping contain water only when the system is being utilized (NO
AUTOMATIC WATER SUPPLY)
◉ Fire Department Connection. Answer: A connection, normally on
the exterior of the building. (FORMERLY KNOW AS SIAMESE
CONNECTION)
◉ Fire Hose. Answer: A flexible conduit constructed of one or more
reinforcements (JACKETS),
◉ Fire Hydrant. Answer: A valve connection on a water supply
system having one or more outlets and that is used to supply hose
and fire department pumps with water.
, ◉ Bulb Sprinkler. Answer: A sprinkler operated by heat breaking a
glass bulb filled with a non-freezing liquid with diamiter that vary
from 3mm for quick response sprinklers to 5mm for standard
response sprinklers.
◉ Hose Connection. Answer: a combination of equipment provided
for connection of a hose to the standpipe system that includes a hose
valve with a threaded outlet.
◉ Hose Station. Answer: a combination of a hose rack, hose nozzle,
hose, and hose connection.
◉ Impairment Coordinator. Answer: Person responsible for
ensuring the proper safety precautions are taken when the fire
protection system is placed out of service (designated by the owner)
◉ In Service. Answer: The Status of hose stored in a hose house, on a
rack or reel, or on a fire apparatus that is available and ready for
immediate use at an incident.
◉ Personal Supervision. Answer: Supervision by the holder of a
department certificate who is required to be personally present on
the premises, or other proximate location acceptable to the