NABCEP PV ASSOCIATE EXAM AND RETAKE EXAM LATEST 2026
ACTUAL EXAM WITH COMPLETE QUESTIONS AND CORRECT
DETAILED ANSWERS (100% VERIFIED ANSWERS) |ALREADY
GRADED A+| ||PROFESSOR VERIFIED|| ||BRANDNEW!!!||
A system that sits on a flat/low slope rooftop and has no
penetrations is called a:
A) Flush mounted system
B) Flashed system
C) BIPV system
D) Ballasted system - ANSWER-Ballasted systems are common
flat low slope roof systems that are not penetrating the roof. A
ballast is something that is relatively heavy keeps the PV from
blowing away
Proper slope for an extension ladder? - ANSWER-1:4
The primary source for a utility interactive PV system is the:
A) Inverter
B) Utility
C) PV
,2|Page
D) Charge controller - ANSWER-Utility. The interactive inverter
will match the voltage and frequency of the utility
What is specified on a charge controller?
A) Irradiance limit
B) Insolation limit
C) Maximum voltage
D) Minimum current - ANSWER-A charge controller will have
maximum voltage specified (and so will most any equipment). A
charge controller will also specify maximum current
Units for irradiance - ANSWER-Irradiance is power per area,
usually measured in watts per square meter. 1000W/m^2 is the
irradiance level called Peak sun, or irradiance at STC. Energy per
area is irradiation or insolation.
What is used to calculate maximum system voltage? - ANSWER-
Temperature is used to calculate maximum system voltage along
with Voc, the temperature coeffient of Voc and the number of PV
modules connected in series.
,3|Page
What will be increased by reflective surfaces (albedo)? -
ANSWER-Current. Reflections and increased light increases
current.
What is the best voltage for charging a 12V lead-acid battery?
A) 12V
B) 11.8V
C) 12.3V
D) 14.1V - ANSWER-14.1 .
Best voltage for charging a 12V battery is 14.1V (best of the
choices given). A 12V lead-acid battery will sit charged at
12.6V and often charge somewhere between 14 and 15V. If a
12V lead-acid battery is at 50% depth of discharge, it will
measure about 12V
Unit for resistance - ANSWER-Ohms
Wind uplift forces in the construction industry in the US are
measured in... - ANSWER-Pounds per square foot (psf)
, 4|Page
Direction on a compass is - ANSWER-Azimuth
Hydraulic analogy for voltage is - ANSWER-Pressure. Current is
flow
Which room cannot have a PV dc disconnect?
A) Kitchen
B) Attic
C) Bathroom
D) Bedroom - ANSWER-Bathroom. PV dc disconnect not allowed
in bathroom (think wet feet)
Stand-alone inverter output goes to: - ANSWER-Loads. Off-grid
inverter output goes to loads. Loads are what use electricity
Best sealant for residential rooftop - ANSWER-Polyurethane and
silicone are the best. Silicone is a sealant, silicon is what solar
cells are made of