ANSWERS 2025
What 3 criteria are needed for interruption of fire protection and life safety systems during effects? -
CORRECT ANSWERS-1) Approval of AHJ
2) Owner or owners agent
3) having a fire watch there at all times
Permanently installed indoor effects can only interrupt during the initial acceptance of the system
Documentation of flame effect - CORRECT ANSWERS-Drawing manuals or written
descriptions of all flame effects must be created and on site, available to AHJ
Must also have written operating instructions including start-up, show operations, normal shutdown
procedures, and emergency shutdown procedures
-Operating instructions must be available to the operator
Housekeeping - CORRECT ANSWERS-premises where flame effect devices are installed or
fired shall be maintained in a neat and orderly condition
Protective clothing - CORRECT ANSWERS-any required should be tested and demonstrated to
be flame retardant
documentation will also be furnished
flame effect operator age - CORRECT ANSWERS-21 and up
Fire - CORRECT ANSWERS-after arm, it is the control system functions that result in the
deliberate release of fuel for ignition
, Flame effect burner - CORRECT ANSWERS-A burner designed to produce specific sizes and
configurations of flames for flame effects
Flame effect material - CORRECT ANSWERS-A flammable material that is used as fuel to
create a flame
Flame effect safety controller - CORRECT ANSWERS-A control system that is part of a flame
effect appliance that is used to prove that the source of ignition is present (flame safeguard control)
Group II flame effect - CORRECT ANSWERS-An individual or group flame effect designed fro
unattended operation that is temporarily or permanently installed outside any sructure (eternal
monument flame)
Group III flame effect - CORRECT ANSWERS-An attended, temporarily installed flame effect
for a specific production with limited operation and fixed time for removal
Group IV flame effect - CORRECT ANSWERS-Large or group flame effect that is permanently
installed inside or outside any structure desined for unattended operation WITHOUT a main show
supervisory control system
Group V flame effect - CORRECT ANSWERS-A large individual or group flame effect that is
temporarily or permanently installed inside or outside any structure and is designed for intermittent or
continuous operation under the supervision of a main show control system, but without full-time
supervision by a technition
Group VI flame effect - CORRECT ANSWERS-A large individual or group flame effect that is
temporarily or permanently installed outside or inside any structure and is designed for intermittent
operation under the supervision of a main show control system and a technical director, with cast
members in close proximity to the effect at the time of operation
Group VII flame effect - CORRECT ANSWERS-an individual flame effect that can be tomprarily
or permanently installed inside or outside any structure that, due to its unique operating requirements,
does not fit into any other classification