2026/2027 COMPLETE QUESTIONS WITH
VERIFIED CORRECT ANSWERS ||
100% GUARANTEED PASS
<NEWEST VERSION>
1. ALARM NOTIFICATION APPLIANCE. - ANSWER ✔ A fire alarm
system component, such as a bell, horn, speaker, light, text display or
vibration device that issues an audible, tactile, and/or visual alert
2. ALARM SIGNAL - ANSWER ✔ A signal indicating an emergency
requiring immediate action, such as a signal indicative of fire.
3. ALTERATION - ANSWER ✔ Any addition to, or modification of, an
existing installation or facility, other than any repair made in the ordinary
course of maintenance.
4. ANNUNCIATOR - ANSWER ✔ A unit containing one or more indicator
lamps, alphanumeric displays, or other equivalent means in which each
indication provides status information about a circuit, condition, or location.
5. ASSEMBLY AREA. - ANSWER ✔ A designated area outside of a building
to which building occupants are directed to report upon implementation of a
partial or full evacuation in accordance with a Comprehensive Fire Safety
and Emergency Action Plan or a fire and emergency preparedness plan.
,6. AUTOMATIC - ANSWER ✔ acting by itself.
As applied to fire protection devices, any device, equipment or system that
initiates system function as a result of a predetermined temperature rise, rate
of temperature rise, or combustion products, without the necessity for human
intervention.
7. BUILDING - ANSWER ✔ An enclosed structure designed or occupied to
house any use or occupancy.
8. BUILDING OCCUPANTS. - ANSWER ✔ All persons in the building,
including employees, building personnel and visitors
9. CENTRAL STATION. - ANSWER ✔ A facility that receives alarm signals
from a protected premises and retransmits or otherwise reports such alarm
signals to the department
must be responsible for monitoring and retransmitting the fire alarm system
signals.
must be certified by the FDNY.
10.Smoke control systems - ANSWER ✔ Mechanical systems that control the
movement of smoke during a fire
11.found in buildings such as hospitals, covered malls or other buildings
containing atriums, high-rise buildings, and buildings with smoke protected
seating.
,12.2 categories of smoke control systems - ANSWER ✔ dedicated systems and
non-dedicated systems.
13.Dedicated systems - ANSWER ✔ Specially produced to perform a single
function or set of functions.
14.are often found in stairways and elevator shafts to prevent the spread of
smoke.
15.Non-dedicated systems - ANSWER ✔ provide HVAC in the building every
day, but are captured by the smoke-control system in the event of a fire.
16.Smoke proof enclosure - ANSWER ✔ an entry enclosure preceding an exit
stair, designed to prevent smoke from entering the stair; used in high-rise
design
17.Stair Pressurization. - ANSWER ✔ Creation and maintenance of pressure
levels in zones of a building, including elevator shafts and stairwells, that are
higher than the pressure level
at the smoke source
18.the process by which fans are activated within a stair enclosure to pressurize
it and prevent smoke from entering that stairway
19.3 type of signals at panel - ANSWER ✔ Supervisory and trouble
, 20.Central station company - ANSWER ✔ A facility that receives alarm signals
from a protected premise and retransmits or otherwise reports such alarm
signals to the FDNY.
21.F-01 - ANSWER ✔ Impairments / something impaired with sprinklers,
standpipe, or fire alarm.
22.F-02 - ANSWER ✔ Specific to shelters
23.F-03 & F-04 - ANSWER ✔ Places of public assembly
24.S-12 - ANSWER ✔ Sprinklers
25.S-13 - ANSWER ✔ Standpipes
26.S-95 - ANSWER ✔ Specific to panels that do not require two way
conversations
27.F-80 - ANSWER ✔ Shelter coordinator
28.F-89 - ANSWER ✔ FLSD. Buildings with more than 100 people, below or
above ground level. Up to 500 people at max.
29.Warden - ANSWER ✔ Responsible for investigating, communicating
through warden phone