In order to accurately estimate the flow of a sanitary sewer overflow (SSO) you must
have: -
Correct Answer-Spill start time, spill end time and spill rate
Providing a plan and schedule to properly manage, operate and maintain all parts of the
sanitary sewer system is the goal of a: -
Correct Answer-A sewer system management plan (SSMP)
What are the basics elements of a safety program? -
Correct Answer-Safety policy,
statement, safety training, accident investigation
What factor must be considered when obtaining an easement for construction and
maintenance of a collection system? -
Correct Answer-Access for equipment and personnel
As the division manager you receive a request from your board or council, and they
want an immediate response. You do not know all the answers you should: -
Correct Answer-Respond with the information available and update them with more
If you were a supervisor of two lead workers, one whose work was exceptionally good
and a second whose work was substandard, what should you do? - Correct
AnswerDiscuss the problem with the substandard foreman and offer to help before any
other action is taken
In selecting pipe material for maximum service life which factor is more important? -
Correct Answer-Life expectancy of pipe
What affects the flow capacity of a sewer line? -
Correct Answer-Pipe size, pipe,
material, grade
When a grade conflict exists between a Water main and a sewer main, which of the
following is the best solution? -
Correct Answer-Have the Water main adjusted and hold the grade on the sewer main
Why is the replacement of wastewater collection systems in some downtown
streets
difficult? -
Correct Answer-Crowding of other underground utilities.
Under what conditions must each member of the rescue service practice permit
space
rescues? -
Correct Answer-At least once a year in simulated situation using non-
Downloaded by Collins Mwaniki
, lOMoAR cPSD| 57629747
representative space
conditions
If the camera becomes wedged during a video inspection, which of the following would
be your first step in solving the problem? -
Correct Answer-Attempt to free the camera with the tag line.
Drawings which are considered "As Built" would be? -
Correct Answer-Corrected
construction drawings showing changes made in the field
installation.
Legally Responsible Officials are required to report category 1 sanitary sewer
overflows:
-
Correct Answer-Within 2 hrs.
Span & Control relates to the number of subordinates who can be supervised
effectively
by one supervisor. At the top level of organizations, what is this number? -
Correct
Answer-9 to
11
What is the best approach to take when handling on-the-job conflicts? -
Correct Answer-
Communicate clearly without attacking the other person or personalizing the
conflict
What tools are used with a power rodder? -
Correct Answer-Spring blades
Tools used for sewer rodding do not include the: -
Correct Answer-Lag screw
What items would you consider when selecting a solution to clear a stoppage in a
sewer? -
Correct Answer-Cause of stoppage
The lowest point on the inside of a pipeline is called the: -
Correct Answer-Invert
Emergency stoppages in pipelines may be cleared safely by use of: -
Correct Answer-
High velocity cleaners (HVC)
Based on new best practices of the common ground alliance for marking underground
utilities, the inquiry identification number for an underground service alert (USA) is
viable for: -
Correct Answer-28 days
Downloaded by Collins Mwaniki ()