Roles, and Procedures Exam UPDATED
ACTUAL QUESTIONS AND CORRECT
ANSWERS
What is the purpose of the High Rise SOP? - CORRECT ANSWER To establish
standardized strategic and tactical objectives for fire operations in high-rise buildings.
What is defined as a high-rise building? - CORRECT ANSWER A building greater
than five stories or 75 feet high.
What is the Attack Stairwell used for? - CORRECT ANSWER Designated for fire
suppression operations.
What is the Evacuation Stairwell used for? - CORRECT ANSWER Designated for
occupant evacuation.
Where is Interior Staging located? - CORRECT ANSWER Two floors below the fire
floor.
What is the role of Lobby Control? - CORRECT ANSWER To manage building
systems, coordinate access, and maintain accountability at high-rise incidents.
What equipment is minimum for the first-in company? - CORRECT ANSWER High-
rise pack, water extinguisher, forcible entry tools, and TIC.
When can elevators be used during a high-rise fire? - CORRECT ANSWER If
equipped with Firefighter Service and the fire is located on the 5th floor or higher.
, What should be considered when placing apparatus at a high-rise incident? - CORRECT
ANSWER Water supply, aerial access, and egress.
What is the first step in the size-up process for a high-rise fire? - CORRECT
ANSWER Exterior View.
What should be determined during the Exterior View size-up? - CORRECT
ANSWER If the building is residential or commercial and if there is an audible alarm
present.
What is the primary goal of the Rescue tactical objective? - CORRECT ANSWER To
secure and maintain viable evacuation and fire attack stairwells.
What should be assessed during the Fire Attack tactical objective? - CORRECT
ANSWER Fire and smoke conditions, size of the fire, and resources available for
attack.
What type of hose lines should be used for initial attack? - CORRECT ANSWER 2" or
2½" hose lines with smooth-bore nozzles.
What is the preferred method of ventilation in high-rise fires? - CORRECT
ANSWER Horizontal Ventilation using smoke ejectors.
What must be done before breaking windows for ventilation? - CORRECT
ANSWER Notify all personnel of falling glass.
What is the purpose of Property Conservation during high-rise incidents? - CORRECT
ANSWER To limit water and smoke damage.
What should be done if strong winds are present during ventilation? - CORRECT
ANSWER Open windows on the leeward side first, then the windward side.