Type ____ is multiconductor cable identified for use as underground service
entrance cable. ---------CORRECT ANSWER-----------------Type USE cable




Knife switch rated for more than 1200 Amps at 250Volts or less ---------CORRECT
ANSWER-----------------Can be used only as isolating switch, shall not be opened
under load




Track lighting with outlets in a bathroom is not allowed because ? ---------CORRECT
ANSWER-----------------Track lighting has receptacle




Where internal combustion engines are used as the prime motor, an on site fuel
supply shall be provided with an on premise fuel supply sufficient for not less than
____ hours full demand operation of the system ---------CORRECT ANSWER----------
-------6 hours




Fixed in place X-ray equipment properly supplied by a branch circuit rated at not
over ____ amperes shall be permitted to be supplied through a suitable
attachment plug cap and hard service cable cord. ---------CORRECT ANSWER---------
--------30 Amps

,Where skin effect exist the ferromagnetic envelope shall be bonded at ____. -------
--CORRECT ANSWER-----------------Both ends




GFCI protection at a carnival is not required for equipment at circuit if the
receptacle is of the ____type. ---------CORRECT ANSWER-----------------Locking




The maximum voltage drop from service point to the last over-current device in a
dwelling unit? ---------CORRECT ANSWER-----------------4%




Which of the following statements best describe the grounding requirement for
central vacuum outlet ---------CORRECT ANSWER-----------------Accessible non
current carrying metal parts are required to be connected to an equipment
grounding conductor.




In healthcare facilities, patient bed receptacles located in general care areas shall
be supplied by at least two branch circuits, which ____permitted to originate
from two separate transfer switches on the emergency system ---------CORRECT
ANSWER-----------------Are permitted

,Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges ,day rooms, or similar areas ---------CORRECT ANSWER-------------
----Do not include




The patient care area is any portion of the healthcare facility where patients are
intended to be ____or ____. ---------CORRECT ANSWER-----------------Examined or
treated




Each general care area patient bed location in a healthcare facility must be
provided with four ____ or ____ duplex receptacles ---------CORRECT ANSWER------
-----------Single or two




A hospital is a building or portion thereof used for medical, psychiatric,obstetrical
, or surgical, care on a 24 hour basis of ____ or more patients ---------CORRECT
ANSWER-----------------Four




Where installed to reduce electrical noise for electronic equipment, electrical
continuity of the metal raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment --------
-CORRECT ANSWER-----------------Listed fitting




Feeder and branch circuit conductors within ____ inches of a Ballast shall have an
insulation temperature rating not lower than 90°C (194°F) unless supplying a

, luminaiere marked as suitable for a different insulation temperature ---------
CORRECT ANSWER-----------------3 inches




Manufactured wiring systems constructed with type MC cable shall be supported
and secured at intervals not exceeding ____ ft. ---------CORRECT ANSWER------------
-----6 ft




Where a main bonding jumper or a system bonding jumper is a screw only the
screw shall be identified with a ____ that shall be visible with the screw installed -
--------CORRECT ANSWER-----------------Green finish




Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to distinguish them
from fuses of higher ampere rating ---------CORRECT ANSWER-----------------
Hexagon




The load for household electric clothes dryer's in a dwelling unit(s) shall be either
____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each
dryer served ? ---------CORRECT ANSWER-----------------5000 watts




Service conductors installed as unjacketed multiconductor cable shall have a
minimum clearance of ____ windows that are designed to be opened, doors,

Geschreven voor

Instelling
NYC Master Electrician
Vak
NYC Master Electrician

Documentinformatie

Geüpload op
24 februari 2026
Aantal pagina's
86
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$24.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StudyWay Capella University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
126
Lid sinds
2 jaar
Aantal volgers
43
Documenten
2146
Laatst verkocht
1 week geleden
INVEST AND UNLEASH THE POWER OF KNOWLEDGE NOW!

THIS PREMIUM STUVIA ACCOUNT GIVES YOU ACCESS TO EXCLUSIVE EXAMS, FLASH CARDS, TEST BANKS, AND STUDY GUIDES TAILORED FOR YOUR SUCCESS. ELEVATE YOUR GRADES, ACCELERATE YOUR LEARNING, AND SUPERCHARGE YOUR STUDIES: DIVE INTO A WORLD OF ACADEMIC EXCELLENCE!

4.4

64 beoordelingen

5
48
4
5
3
3
2
2
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen