WITH ACCURATE RIGHT ANSWERS .
A three dimensional fire often involves static flammable liquid. true or false - Correct Answer -false.
3D firess unvolve flammable liquid in motion as well as both horizontal and vertical surfaces.
Class A fire extinguisher - Correct Answer -are ok for wood, paper, some plastics and textiles. They
offer the coating effects of dry chemicals.
Dry chemical stored pressure fire extinguishers: - Correct Answer -should be removed or replaced at
their next 6 year maintenance or hydrostatic test interval.
B:C - Correct Answer -Talking about UL rating, the _____ rating refers to the amount of sq footage an
extinguisher covers
Class B fire extinguishers cannot handle flammable liquid - Correct Answer -False
employees must be trained in proper use of all portable fire extinguishers according to - Correct
Answer -CRF29
monthly - Correct Answer -you need to have portable fire extinguishers VISUALLY inspected at least
_____ according to 29 CFR 1910.157 (e) (2)
Class A/B fire extinguishers - Correct Answer -should NOT be used forfire that involves live electrical
equipment
annually - Correct Answer -Water or steam fire extinguishers need to be discharged, dissassembled
and inspected at least:
3.5 ft - Correct Answer -An extinguisher weighing over 40 lbs should be installed so the top is no
more than __ from the ground
1
, 50 ft. - Correct Answer -OSHA specified maximum travel distance to an extinguisher for Class B
6 yrs - Correct Answer -dry chem extinguishers requiring 12 yr hydrostatic test must be emptied for
maintenance procedures every
A rated UL extinguishers = how many gallons of water? - Correct Answer -1.25
C - Correct Answer -Class ____ fire extinguishers use electrically nonconductive extinguishing agents
Every 5 years - Correct Answer -Cartridge operated water based portable extinguishers need
hydrostatic testing
stored pressure type extinguishers need need INTERNAL examination : - Correct Answer -never
5 ft above the ground - Correct Answer -extinguishers weighing 40 lbs or less must be installed so
top of canister is no more than _____
K - Correct Answer -class ___ extinguishers are for fires involving cooking media
75 ft - Correct Answer -OSHA specified max travel distance for Class A is ______
C - Correct Answer -proper UL rating to use on electrically energized equipped
Class K - Correct Answer -work on the principle of saponification
Obstacle Type Fires - Correct Answer -involve flammable liquid on a horizontal surface w/ the
presence of a solid object creating a barrier
4 inches - Correct Answer -extinguishers must be installed at least _____ from the ground
Obstacle Type Fires - Correct Answer -may take place in flammable liquid storage caninets, dip tank
process areas, etc.