A supply of spare sprinklers shall be maintained on the
premises. What is the minimum number required? -
Answer-6
The system piping shall be braced to resist both lateral
and longitudinal horizontal seismic loads and to prevent
motion resulting from seismic loads - Answer-true
Torch cutting and welding shall be premitted as a means
for modifying or repairing sprinkler systems. - Answer-false
If the system remains impaired and the licensee does not
have the authority to correct the impairment, the word
impairment must be written across the tag in black letters
that are bold. The licensee shall notify the owner and the
authority having jurisdiction of the impairment in writing no
later than the next business day. - Answer-True
,2|Page
The maximum area of coverage of any sprinkler shall not
exceed 400 ft² - Answer-true
Escutcheons used with recessed, flush type or concealed
sprinklers shall be part of a listed sprinkler assembly -
Answer-true
Tops of risers exceeding three feet in length shall not be
provided with a four way sway brace - Answer-false
Where sprinklers have had paint applied by other than the
sprinkler manufacture, they shall be replaced with newly
listed sprinklers of the same characteristics, including
kfactor thermal response, and water distribution - Answer-
true
Sprinkler piping and fire detection devices shall be
automatically supervised where there are more than
____________ sprinlers on the system. - Answer-20
System water control valves and supply pipes shall not be
properly protected against mechanical damage where
needed. - Answer-false
, 3|Page
In antifreeze systems where pendant sprinklers are
utilized, the water shall not be drained from the entire
system after hydrostatic testing with water. - Answer-false
the system shall BE drained
When talking about preaction and deluge systems all
components of pneumatic, hydraulic, or electrical systems
shall be compatible. - Answer-True
The air supply shall have a capacity capable of restoring
normal air pressure in the system withing 30 minutes. -
Answer-true
A placard shall be placed on the antifreeze system main
valave that indicates __________________ used in the
system.
A. Manufacture type
B. the brand of antifreeze solution
C. Concentration of antifreeze solution
D. volume of the antifreeze solution
E. All of the above. - Answer-E. All of the above