Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

UNIFORM PLUMBING CODE EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026

Rating
-
Sold
-
Pages
4
Grade
A+
Uploaded on
25-02-2026
Written in
2025/2026

UNIFORM PLUMBING CODE EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026 Building drain - Answers That part of the lowest piping of a drainage system that receives the discharge from soil, waste and other drainage pipes inside the wall of a building and conveys it to a point 2 feet outside the building wall. Combination waste and vent system - Answers A horizontal drain that is to provide free movement of air above the flow line of the drain. Flushometer Tank - Answers A device integrated within an air accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes. Wet vent - Answers A vent that is also a drain The vertical depth of a trap seal is measured from - Answers The crown weir to the top of the dip of the trap True or false: restroom facilities in a day care are classified as public use - Answers True A combination sewer is _________________. - Answers Building sewer that conveys both sewage and storm water Invert - Answers Lowest portion of the inside of a horizontal pipe Trap primer - Answers A device and system of piping that maintains a water seal in a remote trap Soldered joint - Answers Joint obtained by the joining of metal parts with metallic mixtures or alloys that melt at a temp up to 840 degrees F Building sub-drain - Answers The portion of a drainage system that does not drain by gravity into the building sewer Boiler blow-off - Answers An outlet on a boiler to permit emptying or discharging of sediment Backwater Valve - Answers A device installed in a drainage system to prevent reverse flow A connection to public sewer or private sewage is required for - Answers Buildings with plumbing fixtures Piping, fixtures, or equipment that are installed so that they interfere with normal operation and use of windows or doors shall be - Answers Relocated to avoid interference When supporting horizontal piping 5" in diameter with hangers, ———-" diameter rod shall be used. - Answers 1/2" All trenches deeper than the footing of any building or structure and paralleling the same must be at least - Answers 45 degrees therefrom Threaded pipe I.P.S. 3/4" (except gas piping) installed horizontally shall be supported - Answers In 10 foot intervals I.P.S. Is an abbreviation for - Answers Iron pipe size Copper tubing installed vertically shall be supported at each story or at maximum intervals of - Answers 10 feet 2" horizontal copper tubing drain pipe shall be supported at - Answers 10 foot intervals Wiped joints are permitted with - Answers Lead Tub waste openings in framed construction shall be protected by - Answers Metal collars or screens Closet bends or stubs shall be cut-off to be even with the top of the _______. - Answers Closet ring Joints at the roof, around pipes, shall be made watertight by the use of - Answers Flashing material Wall mounted water closets shall be securely bolted to - Answers A carrier fitting Fixture connections between drainage pipes and water closets shall be made with - Answers Flanges Sleeves shall be provided to protect all piping through - Answers Concrete and masonry Test gauges shall not hve a pressure more than ——— the test pressure - Answers Twice Screws or bolts for securing floor mounted fixtures shall be - Answers Brass The overflow pipe from a fixture shall be connected on the - Answers House or inlet side of a fixture trap The diameter of a waste and overflow for a bathtub shall not be less than - Answers 1.5" OD The connection of a dishwasher drain directly to the continuous waste is - Answers A code violation Trough urinals shall he - Answers Prohibited With two noted exceptions, all shower compartments and receptors shall be capable of encompassing a _______ diameter circle. - Answers 30" Joints in copper shower pan liners shall be - Answers Soldered or brazed Water closets set side by side shall be no closer than - Answers 30" center to center Manually controlled flushometer valves may be substituted for - Answers One urinal The joint of a wall-hung lavatory, where it is in contact with the wall, shall be - Answers Watertight The tailpiece diameter for lavatories and drinking fountains shall not be less than - Answers 1.25" The clear space in front of any water closet or bidet shall not be less than - Answers 24" Plastic piping for venting water heaters shall be - Answers Approved Vent connectors on natural draft appliances ———— be connected to mechanical draft systems operating under positive pressure. - Answers Shall not A water heater is by definition an appliance for - Answers Supplying hot water for domestic and commercial purposes A three-bedroom home with two bathrooms is equipped with a gas storage-type water heater. The minimum capacity for the water heater in accordance with the first hour ratings is - Answers 67 gallon Outdoor combustion air shall be supplied by - Answers one or two permanent openings Combustion air ducts shall - Answers serve a single space Draft hood-equipped and other fuel-burning Category 1 water heaters may be installed in closets, bedrooms and bathrooms provided ___. - Answers the closet has a listed, gasketed door assembly and a listed self-closing device Where damage may result from leaking water heater, a watertight pan of corrosion-resistant materials should be installed under the water heater when it is located in an attic or - Answers A floor-ceiling assembly Plastic piping may be used to vent a water heater if the water heater is - Answers Listed for use with that material The maximum horizontal length of a 5" vent connector for a water heater shall not exceed - Answers 7.5 feet A water here is installed on the roof of a housing more than 15 feet in height. The code requires ———- to the roof unless other means acceptable to the AHJ are used. - Answers An inside means of access Exit terminals of mechanical draft systems shall not be less than ____ above grade where located adjacent to public walkways. - Answers 7 feet Water heaters installed in residential garages shall be installed so that all burners and burner-ignition devices are located not less than 18 inches above the floor unless - Answers The water heater is listed as flammable vapor ignition resistant Water heaters not listed for outside installation but installed outdoors shall be provided with - Answers Protection to the degree that the environment requires Ballcocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening to f the overflow pipe at least - Answers 1 inch PEX tubing shall not be installed within the first ——— of piping connected to a water heater - Answers 18 inches All malleable iron water fittings shall be - Answers Galvanized Copper water tubing Type "M" may be installed within a building - Answers above ground only After allowing for friction and other pressure losses, the residual water pressure shall be at least - Answers 15psi Galvanized steel piping installed under a concrete floor slab within a building shall - Answers Have a machine-applied coating Water piping may be installed in the same trench with sewer piping made of - Answers Cast iron Building supplies shall be no smaller than that required for the installation and, in no case, smaller than ___ inch(es). - Answers 3/4"

Show more Read less
Institution
UNIFORM PLUMBING CODE
Course
UNIFORM PLUMBING CODE

Content preview

UNIFORM PLUMBING CODE EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2026

Building drain - Answers That part of the lowest piping of a drainage system that receives the
discharge from soil, waste and other drainage pipes inside the wall of a building and conveys it to a
point 2 feet outside the building wall.
Combination waste and vent system - Answers A horizontal drain that is to provide free movement of
air above the flow line of the drain.
Flushometer Tank - Answers A device integrated within an air accumulator vessel that is designed to
discharge a predetermined quantity of water to fixtures for flushing purposes.
Wet vent - Answers A vent that is also a drain
The vertical depth of a trap seal is measured from - Answers The crown weir to the top of the dip of
the trap
True or false: restroom facilities in a day care are classified as public use - Answers True
A combination sewer is _________________. - Answers Building sewer that conveys both sewage and
storm water
Invert - Answers Lowest portion of the inside of a horizontal pipe
Trap primer - Answers A device and system of piping that maintains a water seal in a remote trap
Soldered joint - Answers Joint obtained by the joining of metal parts with metallic mixtures or alloys
that melt at a temp up to 840 degrees F
Building sub-drain - Answers The portion of a drainage system that does not drain by gravity into the
building sewer
Boiler blow-off - Answers An outlet on a boiler to permit emptying or discharging of sediment
Backwater Valve - Answers A device installed in a drainage system to prevent reverse flow
A connection to public sewer or private sewage is required for - Answers Buildings with plumbing
fixtures
Piping, fixtures, or equipment that are installed so that they interfere with normal operation and use
of windows or doors shall be - Answers Relocated to avoid interference
When supporting horizontal piping 5" in diameter with hangers, ———-" diameter rod shall be used. -
Answers 1/2"
All trenches deeper than the footing of any building or structure and paralleling the same must be at
least - Answers 45 degrees therefrom
Threaded pipe I.P.S. 3/4" (except gas piping) installed horizontally shall be supported - Answers In 10
foot intervals
I.P.S. Is an abbreviation for - Answers Iron pipe size
Copper tubing installed vertically shall be supported at each story or at maximum intervals of -
Answers 10 feet
2" horizontal copper tubing drain pipe shall be supported at - Answers 10 foot intervals
Wiped joints are permitted with - Answers Lead
Tub waste openings in framed construction shall be protected by - Answers Metal collars or screens
Closet bends or stubs shall be cut-off to be even with the top of the _______. - Answers Closet ring
Joints at the roof, around pipes, shall be made watertight by the use of - Answers Flashing material
Wall mounted water closets shall be securely bolted to - Answers A carrier fitting
Fixture connections between drainage pipes and water closets shall be made with - Answers Flanges
Sleeves shall be provided to protect all piping through - Answers Concrete and masonry
Test gauges shall not hve a pressure more than ——— the test pressure - Answers Twice
Screws or bolts for securing floor mounted fixtures shall be - Answers Brass
The overflow pipe from a fixture shall be connected on the - Answers House or inlet side of a fixture
trap
The diameter of a waste and overflow for a bathtub shall not be less than - Answers 1.5" OD
The connection of a dishwasher drain directly to the continuous waste is - Answers A code violation
Trough urinals shall he - Answers Prohibited
With two noted exceptions, all shower compartments and receptors shall be capable of encompassing
a _______ diameter circle. - Answers 30"
Joints in copper shower pan liners shall be - Answers Soldered or brazed
Water closets set side by side shall be no closer than - Answers 30" center to center
Manually controlled flushometer valves may be substituted for - Answers One urinal
The joint of a wall-hung lavatory, where it is in contact with the wall, shall be - Answers Watertight

Written for

Institution
UNIFORM PLUMBING CODE
Course
UNIFORM PLUMBING CODE

Document information

Uploaded on
February 25, 2026
Number of pages
4
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
457
Member since
1 year
Number of followers
16
Documents
32154
Last sold
1 day ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.4

74 reviews

5
26
4
16
3
14
2
1
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions