EPA 609 TECHNICIAN CERTIFICATION TEST 2026/2027
BANK 400 QUESTIONS WITH DETAILED VERIFIED
ANSWERS / ALL EXAM QUESTIONS AND VERIFIED
ANSWERS |ALREADY GRADED A+|
Certification for Refrigerant Recovery - ANSWER-Anyone who
recovers refrigerant during the maintenance, service or repair of
small appliances must be certified as either a Universal
Technician or a Type I Technician.
EPA Refrigerant Capture Requirement - ANSWER-EPA
regulations require the capture of at least 80% of the refrigerant
from a small appliance with a non-operating compressor if the
technician is using either type of recovery unit.
Passive System-Dependent Recovery Method - ANSWER-When
using a passive system-dependent recovery method on an
appliance with an operating compressor, you should run the
(appliance's) compressor and recover the refrigerant from the
high side.
, Page |2
Passive System-Dependent Recovery Device - ANSWER-A
passive system-dependent recovery device for small appliances
captures refrigerant in a non-pressurized container.
Sale of CFC and HCFC Refrigerants - ANSWER-The sale of CFC
and HCFC refrigerants is restricted to technicians who are EPA
certified in refrigerant recovery.
EPA-Approved Recovery Devices - ANSWER-none of the above
refrigerants should be recovered with current EPA-approved
recovery devices.
Leak Repair Requirement for Small Appliances - ANSWER-it is
not mandatory to repair the leak but do so whenever.
Permissible Use of Passive Recovery Device - ANSWER-it is
permissible to use a passive recovery device for refrigerant
recovery on a domestic refrigerator.
, Page |3
Schraeder Valves Inspection - ANSWER-it is 'critical' to inspect
the schraeder valve core for bends and breakage.
Damaged Schraeder Valve Core - ANSWER-replace any
damaged schraeder valve core to prevent leakage.
Schraeder Ports Capping - ANSWER-cap the schraeder ports to
prevent accidental depression of the valve core.
Decomposition of R-12 or R-22 - ANSWER-If R-12 or R-22 are
exposed to high temperatures, these refrigerants can decompose
to form hydrochloric and hydrofluoric acids.
Refrigerant venting from charging cylinder - ANSWER-must be
recovered.
Standard vacuum pump for evacuation - ANSWER-can never be
used as a recovery device in combination with a pressurized
container.
, Page |4
EPA Section 608 certification renewal - ANSWER-must be
renewed every 10 years.
Shipping used refrigerant requirements - ANSWER-all of the
above.
Direct service drop-in substitute for R-12 - ANSWER-none of the
above.
System pressure before recovery procedure - ANSWER-0 psig.
EPA definition of a small appliance - ANSWER-Both 'a' and 'b'.
Extra measures for trapped refrigerant release - ANSWER-
passive system-dependent recovery devices on a small
appliances with a non-operating compressor.
Exception to self-contained recovery machine rule - ANSWER-
small appliances.