GUIDE) (MULTIPLE CHOICES) (A+ GRADED 100% VERIFIED) LATEST VERSIO
2025
Study online at https://quizlet.com/_irqptp
1. Servicing Hazardous Drug Compounding Primary Engineering Controls: -
CAG-005-2007
2. Compounding Isolator Testing Guide: CAG-002-2006
3. Secondaring Engineering Controls - Matrix for Sterile Compounding Facilities-
: CAG-008-2010
4. USP 797 Viable Environmental Sampling & Gowning Evaluation: CAG-009-00
5. U.S. Department of Health and Human Services: Guidance for Industry - Sterile Drug
Products Produced by Aseptic Processing : Current Good Manufacturing Process
6. A. National Institute of Occupational Safety and Health
B. Hazardous Drugs List: A. Acronym: NIOSH
B. Used for: __________
7. HEPA & ULPA Filters: IEST-RP-CC001.5
8. Unidirectional-Flow & Clean-Air Devices: IEST-RP-CC002.3
9. Testing Cleanrooms: IEST-RP-CC006.3
10. Calibration Procedures and Guidelines for Select Equipment Used in Testing
Cleanrooms and Other Controlled Environments: IEST-RP-CC013.2
11. HEPA and ULPA Filter Leak Tests: IEST-RP-CC034.3
12. Cleanroom and Associated Controlled Environments - Classification of Air
Cleanliness by Particle Concentration: ISO 14644-1
13. Cleanroom and Associated Controlled Environments - Monitoring to Provide
Evidence of Cleanroom Performance Related to Air Cleanliness by Particle
Concentration: ISO 14644-2
14. Cleanroom and Associated Controlled Environments - Test Methods: ISO
14644-3
15. Cleanroom and Associated Controlled Environments - Design, Construction
and Start-up: ISO 14644-4
16. International Organization of Standards: ISO
17. Controlled Environment Testing Association: CETA
18. Certification Application Guide: CAG
, CETA Study Guide ACTUAL EXAM QUESTIONS WITH COMPLETE SOLUTION
GUIDE) (MULTIPLE CHOICES) (A+ GRADED 100% VERIFIED) LATEST VERSIO
2025
Study online at https://quizlet.com/_irqptp
19. Institute of Environmental Sciences and Technology: IEST
20. United States Pharmacopeia: USP
21. Food and Drug Administration: FDA
22. High Efficiency Particulate Air: HEPA
23. Primary Engineering Control: PEC
24. Direct Compounding Area: DCA
25. Standard Operating Procedure: SOP
26. Laminar Air Flow Workbench: LAFW
27. Colony-forming Unit(s): cfu
28. Beyond-Use Date: BUD
29. Air Changes per Hour: ACPH
30. Biological Safety Cabinet: BSC
31. Trypticase Soy Argar: TSA
32. Feet per Minute: FPM
33. Cubit Feet per Minute: CFM
34. Micro-Grams per Liter: ug/L
35. Micron: µm
36. Decibel: dB
37. Differential Pressure: DP
38. Compounding Aseptic Containment Isolator: CACI
39. Compounding Aseptic Isolator: CAI
40. Occupational Safety and Health Administration: OSHA
41. American Society of Hospital Pharmacists: ASHP
42. ISO 5 Environment: Critical Area
43. A. Daily: How often, at a minimum, should Buffer Room floors be cleaned?
A. Daily
B. Weekly
C. Hourly
D. Yearly
, CETA Study Guide ACTUAL EXAM QUESTIONS WITH COMPLETE SOLUTION
GUIDE) (MULTIPLE CHOICES) (A+ GRADED 100% VERIFIED) LATEST VERSIO
2025
Study online at https://quizlet.com/_irqptp
44. A. Daily: How often, at a minimum, should Ante Room floors be cleaned?
A. Daily
B. Weekly
C. Hourly
D. Yearly
45. C. Monthly: How often, at a minimum, should Buffer Room Shelves be cleaned?
A. Daily
B. Weekly
C. Monthly
D. Yearly
46. B. Monthly: How often, at a minimum, should Buffer Room ceilings be cleaned?
A. Daily
B. Monthly
C. Hourly
D. Yearly
47. D. Monthly: How often, at a minimum, should Buffer Room walls be cleaned?
A. Daily
B. Weekly
C. Hourly
D. Monthly
48. A. Daily: How often, at a minimum, should Ante Room Counters be cleaned?
A. Daily
B. Weekly
C. Hourly
D. Yearly