Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NYC Master Electrician Exam 2025/2026 – 100% Verified Practice Questions & Answers | Latest NEC Code & Electrical License Prep. This document contains 100 % verified practice questions and answers for the NYC Master Electrician Exam 2025/206

Rating
-
Sold
-
Pages
35
Grade
A+
Uploaded on
02-03-2026
Written in
2025/2026

NYC Master Electrician Exam 2025/2026 – 100% Verified Practice Questions & Answers | Latest NEC Code & Electrical License Prep. This document contains 100 % verified practice questions and answers for the NYC Master Electrician Exam 2025/2026, fully updated to the latest National Electrical Code (NEC) and city requirements. It covers essential exam topics such as grounding and bonding, branch circuits, service conductors, fuse identification, voltage drop, clearance rules, healthcare facility wiring standards, and safety regulations. Designed to reflect real exam conditions, this material helps candidates prepare with confidence and maximize their chances of passing on the first try.

Show more Read less
Institution
NYC MASTER ELECTRICIAN
Course
NYC MASTER ELECTRICIAN

Content preview

NYC MASTER ELECTRICIAN EXAM LATEST
2026 QUESTIONS AND VERIFIED ANSWERS|
A+ GRADED

The Value in M ohms of a resistor required to discharge a 30 Mfd
capacitor to safe levels, in the time required by the NYC electrical
Code, that has been energized to 650V is most nearly? 10 - ✔✔✔
ANSWER-



What diameter of a # 14AWG wire is most nearly? .064"inches - ✔✔✔
ANSWER-



What is the short circuit capacity of a 72 KVA transformer with a 240V
secondary and an impedance of 3%? 10,000A - ✔✔✔ ANSWER-



What is the output KW 5000 KVA of a transformer feeding a load that
has a Power Factor Of 80% is: 4000KW - ✔✔✔ ANSWER-



A 100HP DC motor at 220V with 90% efficiency requires a fuse size
of ? 600A - ✔✔✔ ANSWER-



What is the minimum number of duplex receptacles required for each
patient bed in the critical care area of a hospital? 3 - ✔✔✔ ANSWER-



Service switches may be installed on the outside of a building only if:

,The building has only 4 dwelling units or less - ✔✔✔ ANSWER-



The internal bonding bus of a multisection switchboard shall have a
cross section area of at least: 1/2 sq inch. - ✔✔✔ ANSWER-



What is the interrupting capacity of a class H fuse? 10,000 fuse - ✔✔✔
ANSWER-



What is not part of the classification of an incandescent lamp? The
size of the bulb - ✔✔✔ ANSWER-



An electrician buys 100 units of armored cable connectors. He
purchased them at the price of $2.10 each. He then sells them at cost
of $3.00 per unit. Assuming his overhead is 30%, what is his profit. ?
$27.00 - ✔✔✔ ANSWER-



How many 20A branch circuits are required for 80 linear feet of show
window lighting space? 9 circuits - ✔✔✔ ANSWER-



An electrician assigns men to install outlets in a room. It took 2.6
hours to install outlets in each room. At the end of 5 days, how many
rooms are completed? Assume the men work 8hrs a day? 15 - ✔✔✔
ANSWER-



Mandatory rules of the code are those that identify actions that a
specifically required or prohibited and are characterized by the use of
terms: Shall or Shall not - ✔✔✔ ANSWER-

,Which is not considered a power supply? - ✔✔✔ ANSWER-Capacitor



A 15A or 20A 125V receptacle outlet shall be located within 25 feet of
heating, air conditioning, and refrigeration equipment for : dwelling,
commercial, industrial, occupancies. - ✔✔✔ ANSWER-



For other than dwelling occupancies, banks, or office buildings, each
receptacle outlet shall be calculated at not less than 180VA. - ✔✔✔
ANSWER-



The minimum feeder load for show window lighting is 200V per linear
foot. - ✔✔✔ ANSWER-



On a 4 wire, delta connected, the phase system, where the midpoint
of one phase winding is grounded, the conductor with the higher
phase voltage to ground must be durably and permanently marked be
an outer finish orange in color, or other effective means. - ✔✔✔
ANSWER-



The load of electric clothes dryer is a dwelling unit shall be 5000 watts
or the nameplate rating, whichever is larger, per dryer. - ✔✔✔
ANSWER-



A branch circuit that supplies only one utilization equipment is a
individual branch circuit. - ✔✔✔ ANSWER-



The voltage of a circuit is define be the code as the nominal RMS(root
means square) or effective difference of potential between any

, conductors of the circuit. - ✔✔✔ ANSWER-



In New York City for services not rated over 600 volts , you can use
Type ____ cable as long as the cable is enclosed in a threaded metallic
conduit. - ✔✔✔ ANSWER-SE (Service Entry cable)



In strait pull, the length of the box shall not be less than ____ times the
trade size of the largest raceway. - ✔✔✔ ANSWER-8



A separation of at least ____ is required between network
communication cable and power cables. - ✔✔✔ ANSWER-4" (830)



Type ____ is multiconductor cable identified for use as underground
service entrance cable. - ✔✔✔ ANSWER-Type USE cable



Knife switch rated for more than 1200 Amps at 250Volts or less - ✔✔✔
ANSWER-Can be used only as isolating switch, shall not be opened
under load



Track lighting with outlets in a bathroom is not allowed because ? -
✔✔✔ ANSWER-Track lighting has receptacle



Where internal combustion engines are used as the prime motor, an
on site fuel supply shall be provided with an on premise fuel supply
sufficient for not less than ____ hours full demand operation of the
system - ✔✔✔ ANSWER-6 hours

Written for

Institution
NYC MASTER ELECTRICIAN
Course
NYC MASTER ELECTRICIAN

Document information

Uploaded on
March 2, 2026
Number of pages
35
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$22.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
lornezyeng
1.0
(1)

Get to know the seller

Seller avatar
lornezyeng Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
4
Member since
1 year
Number of followers
2
Documents
535
Last sold
2 months ago
Lornezyeng Notes

Hello and welcome to my page. Here you will find all documents, package deals and 100% revised and correct study materials guaranteed A+. My Target is to help students pass course works and those aiming to achieve top marks. Always remember to write a good review when you buy my document and it will be my pleasure for it. I am available to serve you at any time . I hope you find these study materials useful! Wishing you success in your studies.

Read more Read less
1.0

1 reviews

5
0
4
0
3
0
2
0
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions