2026
what is a strongback - Answers set up to distribute pressure
what is the maximum allowable pressure on a soft patch - Answers 150 PSI
what two digits do you dial prior to entering the desired net - Answers 91
what product do you apply to a sounding tape to check the level of fluid in a tank - Answers water
indicating paste
what is the power supply for the P-100 - Answers DFM / JP-5
whose permissions do you need to align an eductor - Answers CO
what are the three types of shoring - Answers I K H
when do you need to shore up a plug - Answers when repair is below the waterline
what are the weight capacities of steel shoring - Answers 6 - 11 6000 - 20000
3 - 5 12000 - 20000
number for DC Central is - Answers 7561
you must push the ______ on the P-100 prior to pulling the cord to start - Answers decompression
lever
what is not included in a plugging kit - Answers hammers
basic "I" type shoring consist of a single beam between an anchor point and a strong back - Answers
true
shoring battens are stronger than wood shoring - Answers false
what are the two sizes of steel shoring and where are they located - Answers 6 - 11
3-5
what is the maximum allowable pressure on a banding patch - Answers 150 PSI
ruptured AFFF piping is also considered hazardous material spill - Answers true
how long does EWARP take to cure - Answers 30 minutes
the electrical submersible pump (ESP) is powered by - Answers 440 V
what is not included in a shoring kit - Answers pencil
what are the three areas of a carpenter's square - Answers heel tongue body
EWARP should not be applied to fuel and potable water - Answers true
what are some materials found in a pipe patching kit - Answers oakum, saw, rubber matting, hammer,
wedges
what is the maximum allowable pressure on a jubilee patch - Answers 100 PSI
what needs to be completed prior to a shoring / pipe patching / plugging team member leaving the
locker with their kit - Answers inventory kit and inform the locker leader
"K" type shoring is the strongest type shoring - Answers false
the plastic pipe patch is used to repair ruptures quickly - Answers false
what NSTM do you find "practical damage control - Answers 079
if steel shoring is wielded in place, you must still provide a shoring watch - Answers false
what is the P-100 rated at - Answers 100 GPM at 83 PSI
the primary and secondary purpose of the P-100 is - Answers firefighting and dewatering
what is the maximum allowable pressure on the EWARP - Answers 150 PSI
to gain suction once P-100 is started you must - Answers open the exhaust valve and priming line until
water is seen at a steady flow when then close the exhaust valve and priming line
2F - Answers gym
2M - Answers post office
2A - Answers MA shack / dispersing
4M - Answers 64 pway
5M - Answers 95 pway
5A - Answers CO's pway
1H - Answers mid hangar bay / portside
3 - Answers aft hangar bay / starboard side
6/7 A - Answers personell
6/7 F - Answers officer country
what are the sizes of the overboard discharge - Answers 2 1/2 & 4
_______ can be used as a suction hose - Answers black non-colapsible hose
how may P-100s are on board USS Bataan - Answers 3