DC 307 ADVANCED DAMAGE CONTROL EXAM QUESTIONS ANSWERED CORRECTLY LATEST UPDATE 2026 what is a strongback - Answers set up to distribute pressure what is the maximum allowable pressure on a soft patch - Answers 150 PSI what two digits do you dial prior to entering the desired net - Answers 91 what product do you apply to a sounding tape to check the level of fluid in a tank - Answers water indicating paste what is the power supply for the P-100 - Answers DFM / JP-5 whose permissions do you need to align an eductor - Answers CO what are the three types of shoring - Answers I K H when do you need to shore up a plug - Answers when repair is below the waterline what are the weight capacities of steel shoring - Answers number for DC Central is - Answers 7561 you must push the ______ on the P-100 prior to pulling the cord to start - Answers decompression lever what is not included in a plugging kit - Answers hammers basic "I" type shoring consist of a single beam between an anchor point and a strong back - Answers true shoring battens are stronger than wood shoring - Answers false what are the two sizes of steel shoring and where are they located - Answers 6 - 11 3 - 5 what is the maximum allowable pressure on a banding patch - Answers 150 PSI ruptured AFFF piping is also considered hazardous material spill - Answers true how long does EWARP take to cure - Answers 30 minutes the electrical submersible pump (ESP) is powered by - Answers 440 V what is not included in a shoring kit - Answers pencil what are the three areas of a carpenter's square - Answers heel tongue body EWARP should not be applied to fuel and potable water - Answers true what are some materials found in a pipe patching kit - Answers oakum, saw, rubber matting, hammer, wedges what is the maximum allowable pressure on a jubilee patch - Answers 100 PSI what needs to be completed prior to a shoring / pipe patching / plugging team member leaving the locker with their kit - Answers inventory kit and inform the locker leader "K" type shoring is the strongest type shoring - Answers false the plastic pipe patch is used to repair ruptures quickly - Answers false what NSTM do you find "practical damage control - Answers 079 if steel shoring is wielded in place, you must still provide a shoring watch - Answers false what is the P-100 rated at - Answers 100 GPM at 83 PSI the primary and secondary purpose of the P-100 is - Answers firefighting and dewatering what is the maximum allowable pressure on the EWARP - Answers 150 PSI to gain suction once P-100 is started you must - Answers open the exhaust valve and priming line until water is seen at a steady flow when then close the exhaust valve and priming line 2F - Answers gym 2M - Answers post office 2A - Answers MA shack / dispersing 4M - Answers 64 pway 5M - Answers 95 pway 5A - Answers CO's pway 1H - Answers mid hangar bay / portside 3 - Answers aft hangar bay / starboard side 6/7 A - Answers personell 6/7 F - Answers officer country what are the sizes of the overboard discharge - Answers 2 1/2 & 4 _______ can be used as a suction hose - Answers black non-colapsible hose how may P-100s are on board USS Bataan - Answers 3 what are the two measuring tools used for shoring - Answers what does esp stand for - Answers electric submersible pump

Meer zien Lees minder
Instelling
DC 307 ADVANCED DAMAGE CONTROL
Vak
DC 307 ADVANCED DAMAGE CONTROL

Voorbeeld van de inhoud

DC 307 ADVANCED DAMAGE CONTROL EXAM QUESTIONS ANSWERED CORRECTLY LATEST UPDATE
2026

what is a strongback - Answers set up to distribute pressure
what is the maximum allowable pressure on a soft patch - Answers 150 PSI
what two digits do you dial prior to entering the desired net - Answers 91
what product do you apply to a sounding tape to check the level of fluid in a tank - Answers water
indicating paste
what is the power supply for the P-100 - Answers DFM / JP-5
whose permissions do you need to align an eductor - Answers CO
what are the three types of shoring - Answers I K H
when do you need to shore up a plug - Answers when repair is below the waterline
what are the weight capacities of steel shoring - Answers 6 - 11 6000 - 20000
3 - 5 12000 - 20000
number for DC Central is - Answers 7561
you must push the ______ on the P-100 prior to pulling the cord to start - Answers decompression
lever
what is not included in a plugging kit - Answers hammers
basic "I" type shoring consist of a single beam between an anchor point and a strong back - Answers
true
shoring battens are stronger than wood shoring - Answers false
what are the two sizes of steel shoring and where are they located - Answers 6 - 11
3-5
what is the maximum allowable pressure on a banding patch - Answers 150 PSI
ruptured AFFF piping is also considered hazardous material spill - Answers true
how long does EWARP take to cure - Answers 30 minutes
the electrical submersible pump (ESP) is powered by - Answers 440 V
what is not included in a shoring kit - Answers pencil
what are the three areas of a carpenter's square - Answers heel tongue body
EWARP should not be applied to fuel and potable water - Answers true
what are some materials found in a pipe patching kit - Answers oakum, saw, rubber matting, hammer,
wedges
what is the maximum allowable pressure on a jubilee patch - Answers 100 PSI
what needs to be completed prior to a shoring / pipe patching / plugging team member leaving the
locker with their kit - Answers inventory kit and inform the locker leader
"K" type shoring is the strongest type shoring - Answers false
the plastic pipe patch is used to repair ruptures quickly - Answers false
what NSTM do you find "practical damage control - Answers 079
if steel shoring is wielded in place, you must still provide a shoring watch - Answers false
what is the P-100 rated at - Answers 100 GPM at 83 PSI
the primary and secondary purpose of the P-100 is - Answers firefighting and dewatering
what is the maximum allowable pressure on the EWARP - Answers 150 PSI
to gain suction once P-100 is started you must - Answers open the exhaust valve and priming line until
water is seen at a steady flow when then close the exhaust valve and priming line
2F - Answers gym
2M - Answers post office
2A - Answers MA shack / dispersing
4M - Answers 64 pway
5M - Answers 95 pway
5A - Answers CO's pway
1H - Answers mid hangar bay / portside
3 - Answers aft hangar bay / starboard side
6/7 A - Answers personell
6/7 F - Answers officer country
what are the sizes of the overboard discharge - Answers 2 1/2 & 4
_______ can be used as a suction hose - Answers black non-colapsible hose
how may P-100s are on board USS Bataan - Answers 3

Geschreven voor

Instelling
DC 307 ADVANCED DAMAGE CONTROL
Vak
DC 307 ADVANCED DAMAGE CONTROL

Documentinformatie

Geüpload op
3 maart 2026
Aantal pagina's
2
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TutorJosh Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
440
Lid sinds
1 jaar
Aantal volgers
16
Documenten
31714
Laatst verkocht
1 dag geleden
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.5

73 beoordelingen

5
26
4
16
3
14
2
1
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen