QUESTIONS ACCURATE AND VERIFIED
ACTUAL EXAM QUESTIONS WITH DETAILED
ANSWERS FOR GUARANTEED PASS |
ALREADY GRADED A
Which of the following monitoring activities should be performed before each patient shift or at
least every four hours?
A. Endotoxin assay
B. Total chlorine level testing
C. Bacterial culture sampling
D. Aluminum concentration testing
Correct Answer: B. Total chlorine level testing
Rationale: Total chlorine (including chloramines) must be tested before each shift or every four
hours to prevent hemolysis and other complications in hemodialysis patients.
Which of the following substances are removed by the water softener?
A. Chlorine and chloramines
B. Bacteria and endotoxins
C. Calcium and magnesium
D. Sodium and potassium
Correct Answer: C. Calcium and magnesium
Rationale: A water softener removes hardness minerals such as calcium and magnesium
through ion exchange, preventing scaling of the reverse osmosis membrane.
According to AAMI standards, the total microbial count of dialysate shall not exceed:
A. 50 CFU/mL
B. 100 CFU/mL
C. 200 CFU/mL
D. 500 CFU/mL
,Correct Answer: C. 200 CFU/mL
Rationale: The Association for the Advancement of Medical Instrumentation (AAMI) sets the
maximum allowable microbial count for dialysate at 200 CFU/mL to ensure patient safety.
The water softener operates on which principle?
A. Filtration
B. Reverse osmosis
C. Distillation
D. Ion exchange
Correct Answer: D. Ion exchange
Rationale: Water softeners function by ion exchange, replacing calcium and magnesium ions
with sodium ions.
Which of the following best describes dialysis-quality water?
A. Untreated municipal tap water
B. Bottled spring water
C. Water treated to meet AAMI standards
D. Distilled water only
Correct Answer: C. Water treated to meet AAMI standards
Rationale: Dialysis-quality water must meet AAMI standards for chemical and microbial
contaminants to be safe for patient use.
Exposure to chloramines during hemodialysis may cause:
A. Hypertension
B. Hemolysis
C. Hyperkalemia
D. Clotting
Correct Answer: B. Hemolysis
Rationale: Chloramine contamination can destroy red blood cells, leading to hemolysis, a life-
threatening complication.
According to AAMI standards, endotoxin levels in dialysate must be less than:
A. 0.25 EU/mL
, B. 1.0 EU/mL
C. 2.0 EU/mL
D. 5.0 EU/mL
Correct Answer: C. 2.0 EU/mL
Rationale: AAMI specifies that endotoxin levels must not exceed 2.0 EU/mL to reduce pyrogenic
reactions.
Percent rejection in reverse osmosis is calculated using which formula?
A. Product conductivity ÷ feed conductivity × 100
B. Feed conductivity – product conductivity ÷ feed conductivity × 100
C. Feed pressure × product pressure
D. Product flow ÷ feed flow
Correct Answer: B. Feed conductivity – product conductivity ÷ feed conductivity × 100
Rationale: Percent rejection measures membrane efficiency by comparing feed and product
conductivity.
A mixed-bed deionization (DI) tank contains:
A. Sodium and chloride
B. Carbon and sand
C. Cations and anions
D. Chlorine and fluoride
Correct Answer: C. Cations and anions
Rationale: Mixed-bed DI tanks contain both cation and anion exchange resins to remove
dissolved ions from water.
Which substance may be added to municipal drinking water to make it clearer?
A. Fluoride
B. Chlorine
C. Aluminum
D. Potassium
Correct Answer: C. Aluminum
Rationale: Aluminum salts are used as flocculants in water treatment to clarify water by causing
particles to clump together.