Quiz :F-01 - Answer :COF for impairment
Quiz :F-60 - Answer :COF for fire guard for torch operation and construction
site
Quiz :G-60 - Answer :Torch operation
Quiz :P-54 - Answer :Crane serial fueling operation at construction site
Quiz :S-92 - Answer :Supervision of portable fueled space heaters
Quiz :S-93 - Answer :Supervising temporary storage and dispensing flammable
or combustible liquids
Quiz :E-21 - Answer :Using powder activated tools
Quiz :A-49 - Answer :Supervision of aerosals
Quiz :G-40 - Answer :Use of LPG CNG for tar kettles, asphalt melter and
marking street line
Quiz :G-44 - Answer :Storage and handling of LPG CNG
Quiz :Pre-Fire Plan - Answer :Shall develop and maintain an approved plan.
Fdny shall be notified of any changes at the jobsite affecting the plan
Quiz :Fire drills - Answer :Held every quarter with recorded results
Quiz :Training - Answer :Review with Employees the use of a portable fire
extinguisher and perform every 6 months.
Quiz :Topics of pre fire plan - Answer :Site safety, fire protection, and tenant
protection, daily log, responder box
Quiz :Structures undergoing demo - Answer :Standpipes shall be maintained
as a dry Standpipe system with air pressurized alarm.
Quiz :Structure Height greater then 75 ft - Answer :Standpipe shall contain air
pressurized alarm system
, Quiz :Weekly Spot checks & visual insp. - Answer :Perform on Standpipes and
gauges of the alarm system
Quiz :Licensed plumber or master fire suppression - Answer :Conduct air
pressure hydrostatic test on all new Standpipe alarms
Quiz :ANSI A13.1 - Answer :Standpipes painted red or ID by lettered legend.
Quiz :OS&Y - Answer :Shall be locked by chain in the open position
Quiz :Combo standpipe - Answer :Valve handles marked yellow
Quiz :Steps for Impairment of Standpipe - Answer :Cease all work, call FDNY,
conduct pre-fire plan, contact super, confirm headcount, call plumber, call
FDNY with corrections, master fire suppression contractor and note all on daily
log.
Quiz :FC 1415.1 - Answer :Fire Code for Fire Extinguishers
Quiz :2A 20: BC - Answer :minimum fire extinguisher rating on the jobsite
Quiz :75 ft & 1,500 sq. ft - Answer :maximum travel distance for fire
extinguishers or area of room
Quiz :multi-floor structures or wood scaffold 40+ ft - Answer :at least one
extinguisher placed near each stair
Quiz :40-B:C - Answer :rating for wheeled fire extinguisher. Kept within 30 ft
from flammable liquid storage cage.
Quiz :2-A rating - Answer :at least 1 fire extinguisher next to each small
ammunition storage area
Quiz :1 per 1,000 sq. ft - Answer :fire extinguisher required with operational
coke salamander temporary heat. Max travel distance is 75 ft.
Quiz :LPG heaters during temp. heating - Answer :at least 1 extinguisher
within 30 feet of heating