Q1. What does the FDNY Certificate of Fitness G-60 authorize the holder to
do?
A. Use open flames in any building
✓ B. Use torches with flammable gases for torch-applied roofing and
similar operations
C. Transport flammable gases across state lines
D. Sell flammable gas cylinders to contractors
Answer: B


Q2. Which regulation governs the use of torches with flammable gas in
New York City?
A. NFPA 58
✓ B. NYC Fire Code Chapter 35
C. OSHA 29 CFR 1926
D. DOT 49 CFR 172
Answer: B


Q3. How far must combustible materials be kept from an open torch flame
during operations?
A. At least 2 feet
B. At least 5 feet
✓ C. At least 10 feet
D. At least 15 feet
Answer: C


Q4. What type of fire extinguisher is required to be on-site during torch
operations?
A. Class A only
✓ B. Class B:C rated extinguisher

, C. Class D only
D. Water-based extinguisher
Answer: B


Q5. What is the minimum fire extinguisher rating required at a torch work
site?
A. 1-A
B. 2-A:10-B:C
✓ C. 4-A:40-B:C
D. 10-B:C
Answer: C


Q6. Before starting torch operations, the Certificate of Fitness holder must:
A. Notify the building owner only
✓ B. Inspect the work area and remove or protect combustible materials
C. Call the local fire company
D. Post a sign on the building entrance
Answer: B


Q7. Who is responsible for maintaining a fire watch during torch
operations?
A. The building owner
B. The NYC Fire Department
✓ C. The Certificate of Fitness holder or a designated person
D. The general contractor only
Answer: C


Q8. How long must a fire watch be maintained after torch operations are
completed?
A. 15 minutes
B. 30 minutes
✓ C. 1 hour
D. 4 hours
Answer: C

,Q9. What is the maximum allowable pressure for a propane torch used in
roofing operations?
A. 5 psi
B. 10 psi
✓ C. As specified by the manufacturer
D. 50 psi
Answer: C


Q10. Which of the following gases is most commonly used for torch-
applied roofing?
A. Acetylene
B. Natural gas
✓ C. Propane (LP-Gas)
D. Hydrogen
Answer: C


Q11. When must a hot work permit be obtained for torch operations in New
York City?
A. Never required
B. Only when working above the 10th floor
✓ C. When required by the NYC Fire Code or building management
D. Only on weekends
Answer: C


Q12. What is the primary hazard associated with torch use in enclosed
spaces?
A. Noise pollution
✓ B. Oxygen depletion and accumulation of flammable gas
C. UV radiation
D. Excessive heat to structural steel
Answer: B

, Q13. When is it permissible to use a torch near a gas meter?
✓ A. Never
B. Only with written approval from the gas utility
C. When the meter is protected by a non-combustible shield
D. When at least 3 feet away
Answer: A


Q14. Which organization issues the G-60 Certificate of Fitness?
A. NYC Buildings Department
✓ B. NYC Fire Department (FDNY)
C. NYC Department of Environmental Protection
D. OSHA
Answer: B


Q15. What action must be taken if a fire is discovered during torch
operations?
A. Continue working and call someone else
✓ B. Immediately stop work, activate alarm, and call 911
C. Use the torch to burn away surrounding combustibles
D. Wait to see if it self-extinguishes
Answer: B


Q16. Which of the following is a requirement for storing LP-Gas cylinders
at a job site?
A. Store in a basement near the water heater
✓ B. Store upright and secured in a well-ventilated area away from
ignition sources
C. Lay flat to prevent rolling
D. Keep inside a heated room in cold weather
Answer: B


Q17. The G-60 Certificate of Fitness must be:
A. Kept at the FDNY office

Written for

Institution
FDNY G 60 — TORCH USE OF FLAMMABLE GAS
Course
FDNY G 60 — TORCH USE OF FLAMMABLE GAS

Document information

Uploaded on
March 6, 2026
Number of pages
65
Written in
2025/2026
Type
Exam (elaborations)
Contains
Unknown

Subjects

$19.09
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Mirror Liberty University
Follow You need to be logged in order to follow users or courses
Sold
425
Member since
3 year
Number of followers
137
Documents
4977
Last sold
1 day ago

3.8

59 reviews

5
23
4
18
3
9
2
4
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions