This document contains updated practice questions and answers designed to help students prepare for the Section 608 Type II certification exam regulated by the United States Environmental Protection Agency. It focuses on high-pressure refrigerant systems, recovery and recycling procedures, leak detection, safety requirements, and environmental regulations related to HVAC servicing. The material provides a structured review of key topics commonly tested on the certification exam.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

EPA SECTION 608 TYPE II
LATEST UPDATE 2024 EXAM
QUESTIONS AND ANSWERS

When first inspecting a hermetic system known to be leaking, you should look for;
a. frost on the tubing
b. puddles of refrigerant.
c. particles of filter drier core.
d. traces of oil.

D

Which part of a belt-driven non-hermetic compressor is most likely to leak if the compressor has
not been used for serval months?
a. Suction service valve.
b. Rotating shaft seal.
c. One or both of the king valves.
d. Head gasket on discharge side.

B

Starting in 2019, what leak rate triggers the EPA requirement that commercial refrigeration
systems containing 50 pounds or more of R-22 be repaired?
a. 10%.
b. 20%.
c. 30%.
d. 35%.

B

A comfort-cooling appliance containing 50 pounds or more of R-22 is found to be leaking
beyond the applicable leak rate threshold. Unless granted additional time, how many days do you
have to repair the leak and conduct the initial leak verification test?
a. 1 day
b. 10 days
c. 30 days
d. 45 days

C

,After a leak repair of a supermarket rack using 3000 lbs. of R-22 and a successful initial
verification test, when must a follow-up leak verification test be conducted?
a. The same day.
b. The next day.
c. Within 10 days.
d. Within 30 days.

C

An initial leak verification test failed after repairing a leak in a rack refrigeration system for a
supermarket using an HCFC refrigerant. What would be the next step(s)?
a. Immediately retrofit or retire the appliance.
b. Conduct additional repairs within the 30-day repair window or mothball the appliance.
c. Conduct a follow-up verification test.
d. Report the amount of refrigerant added to the system to the EPA.

B
Which of the following CANNOT be used as a reason to extend the appliance repair deadlines?
a. Requirements of federal, state, or local regulations make the repair within 30 days impossible.
b. A necessary component is not available.
c. The appliance is located in an area that is subject to radiological contamination.
d. A certified service technician is not available.

D

When a trace gas becomes absolutely necessary, which of the available refrigerants should be
used to help locate a leak?
a. Nitrogen with HCFC R-22.
b. R-22 due to its universal system compatibility and its miscibility with various oils.
c. Nitrogen with a trace amount of the system's design refrigerant.
d. Nitrogen with HFC R-410A.

C

Which of the following is an indicator of a leak in a high-pressure system with a capillary tube?
a. High head pressure
b. Low water temperature
c. Excessive superheat
d. Frequent purging

C

Recovered refrigerant may contain which of the following impurities?
a. Ammonia, carbon dioxide, and methyl chloride

, b. Sodium chloride, potassium nitrate, and silicone oil
c. Sulphur dioxide and methane
d. Acids, moisture, and oil

D

What is the first thing to do when a new system has been assembled and is ready for testing?
a. Pull a vacuum.
b. Pressurize with an inert gas and leak check.
c. Pressurize with the refrigerant to be used in the system.
d. Introduce an initial charge of refrigerant and start the compressor.

B

What is the best use for testing with soap bubbles?
a. To pinpoint refrigerant leaks.
b. To find refrigerant leaks in coil fin area.
c. To detect leaks in water tube condensers.
d. To detect leaks if the condenser is excessively dirty.

A

Which leak repair category does the EPA define as air-conditioning appliances used to provide
cooling in order to control heat and/or humidity in occupied facilities including, but not limited
to, residential, office, and commercial buildings?
a. Commercial refrigeration
b. Industrial process refrigeration
c. Comfort cooling
d. Ice making refrigeration

C
Which of the following additions of refrigerant, when added to an appliance containing 50 or
more pounds of an ozone-depleting refrigerant, triggers the requirement to calculate the leak
rate?
a. Following a retrofit.
b. During the installation of a new appliance.
c. When using a qualified seasonal variance.
d. When topping off the system.

D

What must an owner of a commercial refrigeration appliance with a charge of 2000 pounds of r-
22 do once the leak rate threshold has been exceeded?
a. Take further action by repairing, retiring, mothballing, or retrofitting the appliance.

Geschreven voor

Vak

Documentinformatie

Geüpload op
6 maart 2026
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Testmanstores

Maak kennis met de verkoper

Seller avatar
Testmanstores Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
3 maanden
Aantal volgers
0
Documenten
17
Laatst verkocht
-
banstores

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen