2026/2027 COMPLETE QUESTIONS AND
CORRECT DETAILED ANSWERS || 100%
GUARANTEED PASS RECENT VERSION
A prime coat being used on lime rock, sand-clay, shell, and shell stabilized based
have an application rate of what? - ANSWER Limerock: greater than or equal to
0.10 gal/syd
Sand-Clay, Shell, Shell Base: greater than or equal to 0.15 gal/syd
You do not test overbuild for density unless it is? - ANSWER Greater than one
inch
Where do you find approved tack products? - ANSWER On the FDOT Approved
products list (APL)
During night what is the tack you usually use? - ANSWER PG 52-28 or an
approved emulsion
What tack an you use during the day? - ANSWER Any kind of tack
When determining the specification rate for 52-28 tack you do what? - ANSWER
Multiply the rate by 0.6
What is the tack application rate tolerance? - ANSWER +/- 0.01 gal/syd
, Step 1 for figuring the tack spread rate - ANSWER Find the length of the tack
shot
Station - station = ft
Step 2 for figuring the tack spread rate - ANSWER Find the square yards
feet x width / 9 = syds
Step 3 for figuring the tack spread rate - ANSWER Use the distributor chart to
find the gallons used
start 11/13 - 1319 gal
end 18/14 - 1140 gal
1319 - 1140 = gallons used
Step 4 for figuring the tack spread rate - ANSWER Find the correction factor on
the temperature sheet corresponding to the correct liquid to convert the gallons to
60F
EX: 160F correction factor = 0.9756
gallons used x correction factor = gallons at 60F
Step 5 for figuring the tack spread rate - ANSWER gallons used at 60F / syds =
tack spread rate
What is the application rate for ARMI layers? - ANSWER 0.6 - 0.8 gal/syd
Use the AC(ARB) temperature correction factor
What is the spread rate for the chip spreader? - ANSWER 0.26 to 0.33 ft/syd