Which of the following would not require secondary containment testing?

a.) Interstitial space hydrostatically monitored

b.) Under-dispenser containment

c.) Turbine piping sump

d.) Secondary piping -- ANSWER--a.) Interstitial space hydrostatically monitored

CCR Title 23, Sec 2637(g)



Fiberglass tanks shall be repaired by the following, except:

a.) Small fractures and fissures may be repaired with epoxy

b.) Fiberglass cloth with a minimum dimension 12 x 12 inches centered over the area to be
repaired.

c.) A second layer of fiberglass cloth shall be installed directly over the primary cloth layer
and shall be cut to overlap the primary patch by 5 inches on all sides.

d.) The repaired tank shall be tested for tightness within 30 calendar days following the date
of the completion of the repair. -- ANSWER--c.) A second layer of fiberglass cloth shall be
installed directly over the primary cloth layer and shall be cut to overlap the primary patch by
5 inches on all sides.

CCR Title 23, Sec 2661(d)(4)

, 2


Automatic line leak detectors shall be installed on underground pressurized piping and shall
be capable of detecting a 3-gallon per hour leak rate at 10 psi within 1 hour with a probability
of detection of at least % and a probability of false alarm no greater than %.

a.) 95, 5

b.) 98, 2

c.) 5, 95

d.) 2, 98 -- ANSWER--a.) 95, 5

CCR Title 23, Sec 2636(f)(2) & 2643(c)(1)



An emergency impact valve (shear valve) is found in the following location on an UST
System.

a.) At the turbine piping termination

b.) Base of the dispenser

c.) Under the extractor tee

d.) Spill container -- ANSWER--b.) Base of the dispenser



Notification to perform a secondary containment test must be given to the local agency by:

a.) A service technician or a licensed tank tester.

b.) Cathodic protection tester.

c.) Owner/operator of UST.

d.) State Water Resources Control Board. -- ANSWER--c.) Owner/operator of UST

CCR Title 23, Sec 2637(f)



An owner or operator of an underground storage tank or any part thereof that is destined for a
specific reuse shall advise the local agency, within the time frame specified by that agency, of
all of the following, except:

, 3


a.) The nature of intended use

b.) The name of the new owner and new operator of the UST

c.) The location of intended use

d.) The State Water Resources Control Board must be advised not the local agency --
ANSWER--d.) The State Water Resources Control Board must be advised not the local
agency

CCR Title 23, Sec 2672(b)(4)



Any person(s) installing underground storage tank systems or components shall be certified
or licensed by:

a.) The Contractors State License Board

b.) The local agency

c.) The State Water Resources Control Board

d.) The Regional Water Quality Board -- ANSWER--a.) The Contractors State License Board

CCR Title 23, Sec 2715(g)



The designated UST operator(s) shall perform monthly visual inspections of all UST's for
which they are designated. The monthly visual inspection shall include all of the following,
except:

a.) Inspecting for the presence of hazardous substances, water, or debris in spill containers.

b.) By July 1, 2005, verify that all facility employees have been trained.

c.) Reviewing the alarm history report or log for the previous month.

d.) Inspecting for the presence of hazardous substances, water, or debris in containment
sumps regardless of documentation showing each alarm for the previous month has been
responded to appropriately. -- ANSWER--d.) Inspecting for the presence of hazardous
substances, water, or debris in containment sumps regardless of documentation showing each
alarm for the previous month has been responded to appropriately.

, 4


CCR Title 23, Sec 2715(c)



Which agency approves a site-specific variance which allows for an alternative method of
construction or monitoring:

a.) The Regional Water Quality Board

b.) The State Water Resources Control Board

c.) The Department of Toxic Substance Control

d.) The local agency -- ANSWER--a.) The Regional Water Quality Board

CCR Title 23, Sec 2681(a)



The regulations to enforce compliance of underground storage tank systems in the state are
found in?

a.) Code of Federal Regulations, 40 CFR Part 281

b.) California Code of Regulations, Title 23, Chapter 16

c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 -- ANSWER--b.) California Code of
Regulations; Title 23, Chapter 16



By definition an "underground storage tank system" includes

a.) The tank, all connected piping and dispensers

b.) The tank, all connected piping, ancillary equipment and containment system

c.) Only the tank

d.) Only tanks totally beneath the surface of the ground -- ANSWER--b.) The tank, all
connected piping, ancillary equipment and containment system

Geschreven voor

Instelling
ICC CALIFORNIA UST INSPECTOR
Vak
ICC CALIFORNIA UST INSPECTOR

Documentinformatie

Geüpload op
8 maart 2026
Aantal pagina's
160
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$27.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
KnowledgeFreedom stuvia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
38
Lid sinds
8 maanden
Aantal volgers
1
Documenten
1377
Laatst verkocht
5 dagen geleden
Knowledge_freedom

STUDY SMARTER, GET BETTER GRADES WITH OUR PREMIUM RESOURCES.

4.2

6 beoordelingen

5
4
4
1
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen