2026/2027 WITH ACTUAL CORRECT
QUESTIONS AND VERIFIED DETAILED
ANSWERS |CURRENTLY TESTING
QUESTIONS AND SOLUTIONS|ALREADY
GRADED A+|NEWEST |BRAND NEW
VERSION!!
Ev charging networks?.
• Facilitate EV charging when away from home
• Include maps of all available EV charging stations
• Often allow for app-based charge activiation
• Both a. and c.
• Facilitate EV charging when away from home
• The EV industry is made up of?.
• Auto manufacturers
• Consumer advocacy groups
•EV charging equipment manufacturers
• Research and standards organizations
• All of the above
• All of the above
• Which of the following is the Japanese DC quick charging standard?
• CHAdeMO
• JARI
• Sae
• TEPCO
1|Page
,• CHAdeMO
• An office building has 22 kVA of lighting that is at continuous operation. It also has 35
120-volt duplex receptacles. Both loads are fed from a 300-ampere panelboard operating at
120/240 volts, single phase. How much more continuous load can be added to the service?
• 30,560 VA
• 33,800 VA
• 38,200 VA
• 72,000 VA
• 122K 20-12,50 VO VA = 33,800 VA
72,000 - 33,800 VA = 38,200 VA
38,200 VA × 0.8 = 30,560 VA is the capacity left on the continuous load
• The National Electrical Code (NEC)?.
• Covers all electrical work, from utility generation to household wiring
• Gives minimum installation requirements
• Is a design guide
• Is not intended to provide requirements for installation that safeguard persons and property
from the
• Gives minimum installation requirements
• True or False. Wireless charging equipment is more expensive than coupled EVSE.
• True
• Which of the following articles covers grounding and bonding for electrical systems?
• Article 220
• Article 230
• Article 240
• Article 250
• Article 250
2|Page
,True or false. Conductor operating temperature will have an effect on voltage drop.
• True
• What is covered by NEC 310.15(B)(2)(a) and (B)(2)(b)?
• Ampacity adjustment factors
• Ampacity correction factors
• Voltage drop corrections factors
• Both a. and b.
• Ampacity correction factors
What was the first mass-produced hybrid vehicle?
• GM EV1
• Honda Insight Hybrid
• Tesla Model 3
• Toyota Prius
• Toyota Prius
Charging methods for commercial and industrial Evs include which of the following?
• Above/below bus wireless charging
• Plug-in charging
• Wireless power transfer
• All of the above
• All of the above
Determining the appropriate location for EVSE requires the person planning the installation to
consider which of the following?
• How the customer plans on using the installation
• Location of possible electrical supply points
• The security of the proposed location
• All of the above
3|Page
, • All of the above
Which of the following drive the market for EVs?
• Cheaper gasoline prices
• Decreased cost of electric vehicles
• Increased interest in alternatives to gas powered vehicles
• Both b. and c.
• All of the above
• Both b. and c.
True or False. Receptacle loads for commercial occupancies are based on Section 220.61.?
• False
EVSE signage may be subject to which of the following?
• Local codes and regulations
• Manufacturer restrictions
• Public opinion
• The National Electrical Code
• Local codes and regulations
• Level 2 EVSEs with a rating of 6.6 kilowatts can supply? of charge current when operating at
220 VAC ?
• 20 A
• 30 A
• 40 A
• 50 A
A
• / = P/E
6,600 W/220 VAC = 30 A
4|Page