Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman Oil Maine Fuel Board Rules Exam Questions With Complete Answers

Beoordeling
-
Verkocht
-
Pagina's
27
Cijfer
A+
Geüpload op
09-03-2026
Geschreven in
2025/2026

Journeyman Oil Maine Fuel Board Rules Exam Questions With Complete Answers .What must you do if you notice code violations in a homeowners house? - ANSWERS-Notify them and recommend ways to address them .What must be done when performing an annual tune-up on a heating system? - ANSWERS-A combustion efficiency test and a copy must be posted on site .Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWERS-NFPA 31 .When an emergency arises that does not allow adequate time to get a chimney lined/and or repaired before installing the new heating appliance the licensee may defer the required repairs for how long? - ANSWERS-90 days .What must be performed before a new installation? - ANSWERS-A heat loss system design and load calculation. A copy must be retained to be presented upon request of board inspector .All oil fired BOILERS must be provided with a properly installed and operating what? - ANSWERS-Low Water cut off .Where shall a low water cutoff be installed? - ANSWERS-At the level recommended by the manufacture, but in no case below the crown sheet .If the low water cut off is not installed directly in the boiler where may it be installed? - ANSWERS-Main supply line (vertical riser) as close to boiler as possible, or in a water column of continuous piping attached directly to the boiler .A listed lever or wheel thermally operated oil shut off valve must be installed where? - ANSWERS-At the burner and the oil supply tank .When outside tanks are used a thermally operated shut off valve must be installed where? - ANSWERS-The supply line enters the inside of the building and where the oil line enters the room where the appliance is located .When inside tanks are used and the oil supply tank is installed in a separate room, a thermally shutoff valve must be installed where? - ANSWERS-Where the line enters the room where the appliance is located .Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel or lever type shut-off valve must be installed where? - ANSWERS-At the tank and at the burner .What may be installed in the supply line but not a return line? - ANSWERS-A check valve .All copper oil supply and return lines must be encased in a continuous piece of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the conduit shall not exceed how far from any connection except the connection at fuel tank? - ANSWERS-2 inches .In order to avoid undetected oil leaks under floors, the conduit must be how much bigger than the supply and return lines? - ANSWERS-One pipe size larger .An oil supply line that penetrates a foundation wall must be what? - ANSWERS-Sealed .What must coated copper tubing have installed at the tank when used underground? - ANSWERS-Oils Safety Valve or PRV .When an oil filter or other accessory equipment is connected to a copper piping smaller than 3/4 "and is not directly connected to the oil tank or burner the filter or other device must be what? - ANSWERS-Rigidly supported by wall or floor mounted brackets .What must supply and return lines be connected with? - ANSWERS-Flare fittings .What fittings shall not be used unless for introduction of lines at top of the tank with a single or double tap bushing? - ANSWERS-Compression fittings

Meer zien Lees minder
Instelling
Journeyman Oil Burners Maine
Vak
Journeyman oil burners maine

Voorbeeld van de inhoud

Journeyman Oil Maine Fuel Board Rules Exam
Questions With Complete Answers



\.What must you do if you notice code violations in a homeowners house? -
ANSWERS✔-Notify them and recommend ways to address them


\.What must be done when performing an annual tune-up on a heating system? -
ANSWERS✔-A combustion efficiency test and a copy must be posted on site


\.Whenever a furnace, direct fired hot water heater, or boiler is installed the total
installation must be brought into compliance with what requirements BEFORE
appliance can be fired? - ANSWERS✔-NFPA 31


\.When an emergency arises that does not allow adequate time to get a chimney
lined/and or repaired before installing the new heating appliance the licensee may
defer the required repairs for how long? - ANSWERS✔-90 days



\.What must be performed before a new installation? - ANSWERS✔-A heat loss
system design and load calculation. A copy must be retained to be presented upon
request of board inspector


\.All oil fired BOILERS must be provided with a properly installed and operating
what? - ANSWERS✔-Low Water cut off

,\.Where shall a low water cutoff be installed? - ANSWERS✔-At the level
recommended by the manufacture, but in no case below the crown sheet


\.If the low water cut off is not installed directly in the boiler where may it be
installed? - ANSWERS✔-Main supply line (vertical riser) as close to boiler as
possible, or in a water column of continuous piping attached directly to the boiler


\.A listed lever or wheel thermally operated oil shut off valve must be installed
where? - ANSWERS✔-At the burner and the oil supply tank


\.When outside tanks are used a thermally operated shut off valve must be
installed where? - ANSWERS✔-The supply line enters the inside of the building
and where the oil line enters the room where the appliance is located


\.When inside tanks are used and the oil supply tank is installed in a separate
room, a thermally shutoff valve must be installed where? - ANSWERS✔-Where the
line enters the room where the appliance is located


\.Whenever the oil supply is taken from the top of an oil tank a thermally operated
wheel or lever type shut-off valve must be installed where? - ANSWERS✔-At the
tank and at the burner



\.What may be installed in the supply line but not a return line? - ANSWERS✔-A
check valve

, \.All copper oil supply and return lines must be encased in a continuous piece of
no metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of
the conduit shall not exceed how far from any connection except the connection
at fuel tank? - ANSWERS✔-2 inches


\.In order to avoid undetected oil leaks under floors, the conduit must be how
much bigger than the supply and return lines? - ANSWERS✔-One pipe size larger


\.An oil supply line that penetrates a foundation wall must be what? -
ANSWERS✔-Sealed


\.What must coated copper tubing have installed at the tank when used
underground? - ANSWERS✔-Oils Safety Valve or PRV


\.When an oil filter or other accessory equipment is connected to a copper piping
smaller than 3/4 "and is not directly connected to the oil tank or burner the filter
or other device must be what? - ANSWERS✔-Rigidly supported by wall or floor
mounted brackets



\.What must supply and return lines be connected with? - ANSWERS✔-Flare
fittings


\.What fittings shall not be used unless for introduction of lines at top of the tank
with a single or double tap bushing? - ANSWERS✔-Compression fittings

Geschreven voor

Instelling
Journeyman oil burners maine
Vak
Journeyman oil burners maine

Documentinformatie

Geüpload op
9 maart 2026
Aantal pagina's
27
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
IszackBd University Of Washington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
34
Lid sinds
1 jaar
Aantal volgers
2
Documenten
5115
Laatst verkocht
5 dagen geleden
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Lees meer Lees minder
5.0

3 beoordelingen

5
3
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen