Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Maine State Journeyman Exam up to 15gph Questions With Verified Answers

Beoordeling
-
Verkocht
-
Pagina's
13
Cijfer
A+
Geüpload op
09-03-2026
Geschreven in
2025/2026

Maine State Journeyman Exam up to 15gph Questions With Verified Answers .How many apprentices can a journeyman directly supervise? - ANSWERS-2 .When performing any service work on a customers heating system the licensee must notify the homeowner of? - ANSWERS-Efficiency and code violations .Can a licensed journeyman perform a cleaning on wood/oil combination unit without direct supervision? - ANSWERS-No .When installing a furnace, direct wired water heater or boiler what must be done prior to placing it in service? - ANSWERS-Everything complies with NFPA 31 code .When installing a new oil burner the _______ must be brought into compliance with the rules of the board before ______? - ANSWERS-Wiring Start up .When an emergency situation arises that does not allow adequate time to get the chimney lined/repaired before installing the new heating appliance what can be done? - ANSWERS-90 day waiver .Who is responsible for ensuring repairs or the chimney is lined within the 90 days? - ANSWERS-InstallerLicensee .When is a heat loss required? - ANSWERS-For new install .Prior to a boiler replacement a________ or a ________ Must be conducted before replacement of an existing system. - ANSWERS-Heat loss/ heat load .The low-water cut off must be located where? - ANSWERS-6 inches above boiler crown sheet but in no case below .An oil supply or return line under cement subfloor or earth must be ________ And without ________? - ANSWERS-Sleeved Fittings (continuous) .Coated copper tubing must have _______ Installed at the tank when ________? - ANSWERS-OSV Underground .Whenever an outlet of an oil supply tank is located more than ______ above the burner a _____ or _____ valve is required. - ANSWERS-4ft OSV or PRV .Unprotected lines that are buried or grouted must be? - ANSWERS-removed from service .All fuel supply tanks must be a minimum of _____ From any gas and or solid fuel burning appliance - ANSWERS-5ft .If a customer is converting to an alternative fuel and leaving the oil tank what must be done? - ANSWERS-Vent pipe left in place fill pipe removed and plugged supply lines removed and plugged .Outside oil tank supports shall not be _______? - ANSWERS-Wood .What is the required thickness of the vertical oil tank pad? - ANSWERS-3 inches of solid concrete .When are shims allowed to be used on oil tank legs? - ANSWERS-Never .Oil tanks must be disposed of in accordance with? - ANSWERS-DEP .What are two options for supporting in inside oil tank on unfinished floors? - ANSWERS-3" Cement padssolid concrete blocks .When are vent alarms required on inside oil tanks? - ANSWERS-Always on all tanks 11-5,000 gals .If the entrance to the boiler room is only accessible from the outside the ____________ may be placed _________? - ANSWERS-Emergency switch. At the inside not more than 1 foot away from the door

Meer zien Lees minder
Instelling
Journeyman Oil Burners Maine
Vak
Journeyman oil burners maine

Voorbeeld van de inhoud

Maine State Journeyman Exam up to
15gph Questions With Verified
Answers



\.How many apprentices can a journeyman directly supervise? - ANSWERS✔-2


\.When performing any service work on a customers heating system the licensee
must notify the homeowner of? - ANSWERS✔-Efficiency and code violations


\.Can a licensed journeyman perform a cleaning on wood/oil combination unit
without direct supervision? - ANSWERS✔-No


\.When installing a furnace, direct wired water heater or boiler what must be
done prior to placing it in service? - ANSWERS✔-Everything complies with NFPA
31 code


\.When installing a new oil burner the _______ must be brought into compliance
with the rules of the board before ______? - ANSWERS✔-Wiring Start up


\.When an emergency situation arises that does not allow adequate time to get
the chimney lined/repaired before installing the new heating appliance what can
be done? - ANSWERS✔-90 day waiver

, \.Who is responsible for ensuring repairs or the chimney is lined within the 90
days? - ANSWERS✔-Installer\Licensee



\.When is a heat loss required? - ANSWERS✔-For new install


\.Prior to a boiler replacement a________ or a ________ Must be conducted
before replacement of an existing system. - ANSWERS✔-Heat loss/ heat load



\.The low-water cut off must be located where? - ANSWERS✔-6 inches above
boiler crown sheet but in no case below


\.An oil supply or return line under cement subfloor or earth must be ________
And without ________? - ANSWERS✔-Sleeved Fittings (continuous)


\.Coated copper tubing must have _______ Installed at the tank when ________?
- ANSWERS✔-OSV Underground


\.Whenever an outlet of an oil supply tank is located more than ______ above the
burner a _____ or _____ valve is required. - ANSWERS✔-4ft OSV or PRV



\.Unprotected lines that are buried or grouted must be? - ANSWERS✔-removed
from service


\.All fuel supply tanks must be a minimum of _____ From any gas and or solid fuel
burning appliance - ANSWERS✔-5ft

Geschreven voor

Instelling
Journeyman oil burners maine
Vak
Journeyman oil burners maine

Documentinformatie

Geüpload op
9 maart 2026
Aantal pagina's
13
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
IszackBd University Of Washington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
34
Lid sinds
1 jaar
Aantal volgers
2
Documenten
5115
Laatst verkocht
6 dagen geleden
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Lees meer Lees minder
5.0

3 beoordelingen

5
3
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen