2026/2027 COMPLETE QUESTIONS WITH
CORRECT DETAILED ANSWERS || 100%
GUARANTEED PASS LATEST VERSION
1. A 1-hour-rated fire barrier wall assembly terminates at a ceiling. What fire
resistance rating must the ceiling have to maintain vertical continuity?
a. ½ hour
b. 1 hour
c. 2 hour
d. 3 hour - ANSWER B. 1 hour
2. The required degree of fire resistance-rated separation for an exit stair
enclosure depends on:
a. The height of the building
b. The number of stories or floor levels the exit stair connects
c. Occupant load
d. The building's occupancy type - ANSWER B. The number of stories
or floor levels the exit stair connects
3. The door of a hospital leads to the outside of the building on the street floor.
This door is considered an exit by NFPA 101 definition.
a. True
b. False - ANSWER A. True
4. The forces required to open any door leaf manually to its manually required
width in a means of egress for a new building may not exceed:
, a. 15 lbf
b. 25 lbf
c. 30 lbf
d. 50 lbf - ANSWER A. 15 lbf
5. Select the correct statement.
a. Locks are never allowed on patient sleeping room doors.
b. Locks on patient sleeping room doors are allowed if they do not
restrict egress from the room.
c. Locks on patient sleeping room doors are allowed if they are operable
only by the patient from the room side.
d. Locks on patient sleeping room doors are allowed if staff can readily
unlock the door. - ANSWER D. Locks on patient sleeping room
doors are allowed if staff can readily unlock the door.
6. Guards are required on walking surfaces where there is a vertical drop of at
least:
a. 10 in.
b. 15 in.
c. 20 in.
d. 30 in. - ANSWER D. 30 in.
7. Horizontal exits:
a. Provide passage to the public way
b. Typically include stairs or ramps
c. May not contain doors
d. May not provide more than one-half of the required number of exits -
ANSWER D. May not provide more than one-half of the required
number of exits
8. Which of the following is permitted as a means of egress in a Health Care
occupancy?
, a. Fire escape stairs
b. Enclosed interior stair
c. Fire escape slide
d. Escalator - ANSWER B. Enclosed interior stair
9. Occupant load factors for each occupancy type are established in:
a. Table 7.3.1.2
b. Table 7.3.3.1
c. Table 18.4.3.2
d. Table A.7.6 - ANSWER A. Table 7.3.1.2
10.The clear width of door egress components:
a. May contain no projections
b. May contain projections of not more than 7 inches
c. May contain projections of 9 inches
d. Is measured at the narrowest point of the egress component -
ANSWER D. Is measured at the narrowest point of the egress
component
11.The most restrictive component is the component with the:
a. Smallest clear width
b. Lowest egress capacity
c. Highest capacity factor
d. Smallest capacity factor - ANSWER B. Lowest egress capacity
12.Where an exit serves more than one story, the required egress capacity is: