Inspector Complete Exam Study
Questions with Correct answers
1. Max height of lumber piles exterior - ANSWER 20' high
2. Max length of dead end corridor - ANSWER 20'
3. Min diameter pipe for vehicle crash protection - ANSWER 4"
4. How long can out of service commercial fuel tanks be out of service before
being removed (underground) - ANSWER 365 days
5. A recreational fire shall not be within ? Of a structure - ANSWER 25'
6. Means of egress ceiling min height? - ANSWER 7'6"
7. When It's increased, the increased occupant load will never exceed ? Per
occupant - ANSWER 7sq ft per
8. Smallest width ever allowed for an egress door - ANSWER 32"
9. Doors shall swing in direction of travel where room/area serves occupant
load of ? Or more people - ANSWER 50 or more
10.Max rise of a single run of stairs - ANSWER 12'
,11.Horizontal exits must comply with which sections of IBC and have what fire
rating - ANSWER 1. Section 711&716 of IBC
12.2. Min fire rating of 2 hours
13.No smoking or flames within how far of a aircraft fuel transfer location -
ANSWER 50'
14.Clear space needed on all sides of a spray booth how far? - ANSWER 3'
15.1-51 The minimum width of means of egress doors openings must be
sufficient for the occupant load therefore and must provide a minimum clear
opening width of (BLANK). *Exceptions Ignored* - ANSWER A. 32
inches (IBC 1010.1.1)
16.1-52 A business is storing Class 2 hazardous liquid water-reactive materials
on it premises. The amount of material to be stored is 1 gallon during part of
the year and 20 gallons during part of the year. Does this operation require
an operational permit as required by international fire code. - ANSWER A.
Yes (IFC Table 105.5.22)
17.1-53 An operational permit is required for the storage, use or handling at
normal temperature and pressure (NTP) of compressed gases. If these gases
are corrosive, what is the maximum amount, in cubic feet at NTP, that can
be stored without an operational permit. - ANSWER A. 200 (IFC Table
105.5.9
18.1-54 The minimum aisle width of assembly seating where the aisle does not
serve more than 50 seats is (BLANK). - ANSWER B. 36 inches (IBC
1030.9.1)
, 19.1-55 Where egress doors are used in pairs, approved automatic flush bolts
will be permitted to be used, provided that the door leaf having the
automatic flush bolts has no (BLANK) or surface-mounted hardware. -
ANSWER A. Doorknob (IBC 1010.2.4)
20.(1 - 1) Stairways that are part of the means of egress for the exterior provide
a minimum clear width of (BLANK) between handrails? - ANSWER D. 48
inches ( IBC 1009.7.4)
21.1-2 What is the minimum density allowable for foam plastic used as interior
trim ? - ANSWER B. 20 Pounds per Cubic Foot (IBC 2604.2.1)
22.1-13 An area where persons unable to use stairways can remain temporarily
to await instructions or assistance during emergency evacuation. -
ANSWER B. Area of refuge (IBC Chapter 2 Definitions)
23.1-27 (BLANK) are required to conduct a carnival or fair. - ANSWER B.
Operational permit (IFC 105.5)
24.1-28 What is the fire resistance rating requirement for the primary structural
frame including columns, girders, trusses excluding roof support members in
a Type I-B structure. - ANSWER C. 2 hours (IBC Table 601)
25.1-29 What is the occupant load of a building that was formerly a warehouse
and has recently been turned into a nightclub. The area of the facility
measures 100 feet by 150 feet. As a nightclub, it will contain unconcentrated
tables and chairs around a large dance floor. - ANSWER C. 1000 persons
(fire inspections 7th edition)