The temperature of concrete may be measured in a wall
form. True or False ✓ ✓ ...... ANSWER ....... True
The sensor of the temperature measuring device shall be
submerged a minimum of _____ in. into the freshly mixed
concrete. ✓ ✓ ...... ANSWER ....... 3 in.
, Page 2 of 61
Portions of a composite sample shall be thoroughly remixed
bfore beginning tests on the sample. True or False? ✓ ✓ ......
ANSWER ....... True
The temperature measuring device shall have a capacity of
measuring temperature of freshly mixed concrete to +- _____
degrees F [+- _____ C] throughout a range of _____. ✓ ✓ ......
ANSWER ....... 1 degree F, 30 degrees F to 120 F
The temperature measuring device shall be calibrated _____,
or whenever there is a question of _____. ✓ ✓ ...... ANSWER
....... Annually, accuracy
The temperature of concrete may be measured in a
wheelbarrow. True or False? ✓ ✓ ...... ANSWER .......
True
A composite sample of concrete is required even if the only
purpose for obtaining the sample is to determine
temperature. True or False? ✓ ✓ ...... ANSWER .......
False
, Page 3 of 61
What must be done to the sample container prior to
sampling the concrete? ✓ ✓ ...... ANSWER .......
Dampen with water
What must be done to the concrete surrounding the
temperature measuring device after the device is submerged
in the fresh concrete. ✓ ✓ ...... ANSWER ....... Gently
press the concrete around the temperature measuring
device at the surface of the concrete
How long must the temperature measuring device remain in
the freshly mixed concrete? ✓ ✓ ...... ANSWER ....... At
least 2 minutes but not more than 5 minutes
After the temperature of the concrete is read, what is
required? ✓ ✓ ...... ANSWER ....... Reporting of
temperature
The temperature of concrete is reported to the nearest _____
degrees F ✓ ✓ ...... ANSWER ....... 1 degree F
, Page 4 of 61
According to ASTM C1064, what is one reason to take the
temperature of concrete? ✓ ✓ ...... ANSWER ....... Verify
conformance to a specified requirement for temperature of
concrete
A maximum temperature of freshly mixed concrete is
specified in ASTM C1064. True or False? ✓ ✓ ...... ANSWER
....... False
This method covers sampling from four types of mixtures
which are _____, _____, _____, and _____. ✓ ✓ ...... ANSWER
....... Stationary mixers, paving mixers, revolving drum
mixers, and open top mixers
The maximum allowable time between obtaining the first
and final portions of a composite sample is _____ minutes.
✓ ✓ ...... ANSWER ....... 15
The maximum elapsed time allowed between obtaining the
final portion of the composite sample and beginning the
tests for slump, temperature, and air content is _____
minutes. ✓ ✓ ...... ANSWER ....... 5