1. What are the minimum lighting requirements for a transfer work area and connection
points during a transfer operation?
A. 0.5 ft-candle for work area and 2 ft-candles for connections
B. 1.0 ft-candle for work area and 5.0 ft-candles for each connection point
C. 2.0 ft-candles for work area and 10 ft-candles for connections
D. 5.0 ft-candles for work area and 1.0 ft-candle for connections
Correct Answer: B. 1.0 ft-candle for work area and 5.0 ft-candles for each connection point
Rationale: Adequate lighting ensures safe monitoring of transfer operations and proper visibility
at hose and flange connections.
2. How long must a completed Declaration of Inspection (DOI) be retained?
A. 7 days
B. 30 days
C. 3 months
D. 1 year
Correct Answer: B. 30 days
Rationale: The DOI must be retained for one month from the date it is signed for compliance
verification.
3. When is the official beginning of a transfer operation considered to occur?
,A. When the transfer pump starts
B. When hoses are connected
C. When the Persons-in-Charge meet to complete the DOI
D. When cargo valves are opened
Correct Answer: C. When the Persons-in-Charge meet to complete the DOI
Rationale: Regulations define the start of the transfer as the meeting of the PICs to complete
the DOI.
4. If adequate containment cannot be provided during a fuel transfer, what type of nozzle
must be used?
A. Manual shutoff nozzle
B. Automatic back-pressure shutoff nozzle
C. Gravity feed nozzle
D. Open flow nozzle
Correct Answer: B. Automatic back-pressure shutoff nozzle
Rationale: This nozzle automatically stops flow when back pressure occurs, reducing spill risk.
5. What is the minimum bolt requirement for ANSI flange connections?
A. One bolt per two holes with no minimum
B. A bolt in every hole
C. A bolt in every other hole with a minimum of four bolts
D. Two bolts minimum regardless of flange size
Correct Answer: C. A bolt in every other hole with at least four bolts
Rationale: ANSI flanges require secure fastening but allow alternating bolts provided at least
four are installed.
6. What bolt configuration is required for non-ANSI flange connections?
A. Bolts in every other hole
B. Bolts in every hole
, C. Minimum of two bolts
D. One bolt per flange quadrant
Correct Answer: B. Bolts in every hole
Rationale: Non-ANSI connections require full bolting to ensure structural integrity.
7. How accurate must pressure gauges used during transfers be?
A. Within 5% of actual pressure
B. Within 10% of actual pressure
C. Within 15% of actual pressure
D. Within 20% of actual pressure
Correct Answer: B. Within 10%
Rationale: Pressure gauges must be reasonably accurate to ensure safe monitoring of transfer
pressures.
8. Where is minor leakage allowed on transfer pumps?
A. Shaft seals
B. Pump casing
C. Packing glands
D. Hose connections
Correct Answer: C. Packing glands
Rationale: Packing glands may allow minimal controlled leakage to lubricate packing and
prevent overheating.
9. Which of the following best defines a MARPOL reception facility?
A. A facility that stores cargo oils only
B. A facility capable of receiving oily mixtures, NLS residues, or garbage from ships
C. A shipboard tank used to collect waste
D. A temporary spill containment system
Correct Answer: B. Facility capable of receiving shipboard wastes