CSA Standard W59 covers the welding requirements for what type of steel
construction?
The welding requirements of CSA Standard W59 can be applied to carbon and
low-alloy welded steel
What types of structures are covered in CSA Standard W59?
CSA Standard W59 covers statically- and cyclically-loaded (repetitive loading)
structures.
What is a low-hydrogen electrode?
A low-hydrogen electrode is an electrode that deposits weld metal with a
specified maximum limit of diffusible hydrogen.
1/19
,3/15/26, 5:00 PM CSA W47.1 and CSA W59 Exam questions
What are the requirements for contractor certification?
When mandated in the contract or in the governing design Standard*, all
Contractors performing work under this Standard must be certified to CSA
W47.1 for welded fabrications.
What welding processes are covered in CSA Standard W59?
This standard covers the SMAW, GMAW, GTAW, MCAW, FCAW, SAW, ESW, EGW
and SW processes.
What is a partial joint penetration groove weld?
A partial joint penetration groove weld is defined as one
having joint penetration less than complete
Does CSA Standard W59 allow for the use of intermittent groove welds?
No. Groove welds must be continuous for the full length of the joint or as
otherwise permitted by the Engineer.
The Term Bureau Means:
Canadian Welding Bureau
In this standard the term contractor means:
Fabricator or Erector
2/19
, 3/15/26, 5:00 PM CSA W47.1 and CSA W59 Exam questions
Welding terminology shall be defined as:
AWS Standard A3.0
Preheat required for a CAN3-G40.21m 350W Steel, 20mm thick, at an ambient
temperature of -5°C, using E48018 electrode
10°C
The maximum gap permissible after assembly of a butt joint to be groove
welded, with steel backing bar, and with a root opening of 6 mm:
12mm
The largest size notch in a flare cut edge that the fabricator can remove by
grinding without approval is:
5mm
A 6 mm fillet weld, the actual minimum size must be deposited if the gap between
par is
0.8 mm:
6mm
Which type of weld is prohibited for dynamically loaded structures:
Slot Weld
For the purpose of CSA W59 standard, welds shall be classified as:
all of the above (Plug, Fillet, Groove).
3/19